"dev" <dev-boun...@openvswitch.org> wrote on 07/08/2016 02:38:06 AM:

> From: Gurucharan Shetty <g...@ovn.org>
> To: dev@openvswitch.org
> Date: 07/08/2016 12:36 PM
> Subject: [ovs-dev] [PATCH 2/2] ovn-controller: Change strategy for
> gateway conntrack zone allocation.
> Sent by: "dev" <dev-boun...@openvswitch.org>
>
> Commit 263064aeaa31e7 (Convert binding_run to incremental processing.)
> changed the way patched_datapaths were handled. Previously we would
> destroy the datastructure in every run and re-create it fresh. The new
> way causes problems with the way conntrack zones are allocated as now
> we can have stale port_binding entries causing segmentation faults.
>
> With this commit, we simply don't depend on port_binding records in
> conntrack zone allocation and instead store the UUID as a string in
> the patch_datapath datastructure.
>
> Fixes: 263064aeaa31e7 ("Convert binding_run to incremental processing.")
> Signed-off-by: Gurucharan Shetty <g...@ovn.org>
> ---

I like what this is doing, but I'd like it more if it had a test case
that would fail without this patch, but pass with it, so that we don't
regress...

Ryan

_______________________________________________
dev mailing list
dev@openvswitch.org
http://openvswitch.org/mailman/listinfo/dev

Reply via email to