On Fri, Jan 29, 2016 at 8:36 PM, Darrell Lu <dlu...@gmail.com> wrote:
> The following is a proposal regarding how to allow logical
> and physical endpoint contexts for OVN to stay separated, from
> a CMS POV.
>
> A logical endpoint has the form: ls1-port1.
> A physical endpoint has the general form:
> chassis/physical port or location on chassis/encapsulation.
>
> Some advantages for cleanly separating logical and physical
> layers are:
>
> 1) Logical and physical domains can be managed separately; for
>    example, by different companies or business units, with minimal
>    interaction overhead.
>
> 2)The physical layer details can change without needing to
>    change the logical layer; for example, a physical endpoint
>    vlan can change without needing to change the logical layer,
>    which in OVN resides in the NB DB.
>    The physical endpoint encapsulations can even change in future,
>    without needing to update the NB DB supported options and/or
>    churning the NB DB.
>
> 3) The logical configuration remains simple in that it just needs
>    to concern itself with tasks such linking users to services,
>    without too much concern about where the services
>    or users are presently located.
>
>
> A physical topology CMS or sub-component of a CMS can be
> used to configure physical endpoints in the SB DB directly,
> bypassing the NB DB and northd processing.
>
>
> A new Physical_Endpoint table describes endpoints used to reach a
> physical network only, including localnet and gateway cases.
>
>
> This physical topology CMS would write to this new table.
>
> Physical_Endpoint TABLE
>
> Summary:
>      Core Features:
>          name             string (must be unique within table)
>          chassis          chassis record
>          chassis_port     string
>          type             string
>          ingress_encap    string
>          egress_encap     string
>
>
> Details:
>      Core Features:
>           name: string (must be unique within table)
>                     A physical_endpoint name which can be used to describe
> its
>                     connection role.
>           chassis: chassis record.
>           chassis_port: string
>                     Physical port with the context the associated chassis.
>           type: string, can be single vlan, which is presently supported.
>                     In future, a tunnel type such as MPLS/IP tunnels or
>                     multiple vlans might be used. Nomenclature is TBD.

Is there any reason to restrict this to a VLAN from the start? If we
allow it to be a VXLAN VNI, we could in theory make use of VXLAN
tunnels for these as well as VLANs. This would help us to solve this
requested feature in Neutron [1] for example, which is to support
VXLAN encap for external routers in addition to VLANs.

[1] https://bugs.launchpad.net/neutron/+bug/1525059

>           ingress_encap: string
>                     Encapsulation expected for packets received on this
>                     physical endpoint. Incorrect encapsulation will
>                     result in packet drop.
>           egress_encap: string
>                     Encapsulation used for packets transmitted on this
>                     physical endpoint.
>                     If type is vlan, ingress_encap == egress_encap as
>                     per existing OVN expected behavior.
>
> A new ovn-sbctl command can be used in lieu of CMS support.
>
> ovn-sbctl phys-endpt-add phys_endpt_name chassis_name chassis_port type
>                          ingress_encap egress_encap
>
>
> The existing Port Binding table is modified for localnet and gateway cases.
> options : phys_endpt was added for gateways.
> options : phys_endpt replaces tag for localnet.
> Note that there is some redundancy in information, as phys_endpt
> includes chassis and there is a separate column for chassis in the
> Port Binding table.
>
> Port_Binding TABLE
> .
> .
> .
>
>    Summary:
>        Core Features:
>          datapath                    Datapath_Binding
>          logical_port                string (must be unique within table)
>          chassis                     optional weak reference to Chassis
>          tunnel_key                  integer, in range 1 to 32,767
>          mac                         set of strings
>          type                        string
>        Patch Options:
>          options : peer              optional string
>        Localnet Options:
>          options : network_name      optional string
>          options : phys_endpt        optional physical endpoint record
>        VTEP Options:
>          options : vtep-physical-switch
>                                      optional string
>          options : vtep-logical-switch
>                                      optional string
>          options : phys_endpt        optional physical endpoint record
>        Nested Containers:
>          parent_port                 optional string
>          tag                         optional integer, in range 1 to 4,095
> .
> .
> .
>    Details:
>       Localnet Options:
>           These options apply to logical ports with type of localnet.
>
>            options : phys_endpt: optional physical endpoint record
>                   Used to derive physical port, ingress encapsulations
>                   and egress encapsulations.
> .
> .
>       VTEP Options:
>           These options apply to logical ports with type of vtep.
>
>           options : phys_endpt: optional physical endpoint record
>                   Used to derive physical port, ingress encapsulations
>                   and egress encapsulations.
> .
> .
> .
>
> The existing ovn-sbctl lport-bind command syntax is not modified so as not
> to impact existing HV support. This may be TBD.
>
> A new ovn-sbctl command is added for use in localnet and gateway cases.
> The below command should be used in place of ovn-sbctl lport-bind for
> localnet and gateway cases.
>
> ovn-sbctl lport-bind-phys-endpt logical-port phys-endpt-name
>
>        [--may-exist] lport-bind-phys-endpt logical-port phys-endpt-name
>               Binds the logical port named logical-port to phys-endpt.
>
>               Without  --may-exist, attempting to bind a logical port that
> has
>               already been bound is an error.  With --may-exist, this
>  command
>               does  nothing  if logical-port has already been bound to a
>               phys-endpt.
>
>        [--if-exists] lport-unbind-phys-endpt logical-port phys-endpt-name
>               Resets the binding of logical-port to NULL.
>
>               Without --if-exists, attempting to unbind a logical port that
> is
>               not  bound  is an error.  With --if-exists, attempting to
> unbind
>               logical port that is not bound has no effect.
>
> Darrell
> _______________________________________________
> dev mailing list
> dev@openvswitch.org
> http://openvswitch.org/mailman/listinfo/dev
_______________________________________________
dev mailing list
dev@openvswitch.org
http://openvswitch.org/mailman/listinfo/dev