On Mon, Mar 3, 2014 at 11:00 PM, Ben Pfaff <b...@nicira.com> wrote:
> The above data structure isn't needed; OVS already handles experimenter
> error codes through infrastructure in ofp-error.h.  You can update that
> file with any new error types or codes.
>
> The various generic "property" definitions here have the same form as
> those already used various places in OpenFlow and in particular in the
> "table features" definitions in OpenFlow 1.3.  I'd prefer to handle them
> generically rather than building up new infrastructure for each instance
> of such properties in OpenFlow.  I'm working on that for "table
> features" but I've been pretty slow about it.  Maybe I can catch up
> soon.

Well, these experimenter codes and generic property definitions are not
used for the moment by this feature. Maybe I should just remove them
from here for the time being.
And I agree that it would be best to treat them in a generic way.