I was refering to ALT CONSOLE, it could be used to any other device.
Not only SLCD :-)

Maybe it was removed because now there is another alternative to
Alternative Console, hehehe. I need to check.

On 9/27/22, Jernej Turnsek <jernej.turn...@gmail.com> wrote:
> Hi Alan,
>
> what do you mean about someone removing the nsh console. It is still in
> apps repo. Your video was actually using a different slcd console which is
> available for alphanumeric lcd displays.
>
> Regards,
> Jernej
>
> On Tue, Sep 27, 2022 at 3:05 PM Alan C. Assis <acas...@gmail.com> wrote:
>
>> Hi Jernej,
>>
>> NSH used to be an Alternative Console, but I think someone removed it
>> few months ago, probably now my video tutorial explaning show to put
>> the NSH terminal in a matrix display will not work see:
>>
>> https://www.youtube.com/watch?v=4za1lhfsct8
>>
>> Maybe someone who removed it could help us :-)
>>
>> BR,
>>
>> Alan
>>
>> On 9/27/22, Jernej Turnsek <jernej.turn...@gmail.com> wrote:
>> > Hi,
>> >
>> > I have enabled nxterm functionality on my board with a 400x240 display
>> and
>> > I am using an USB console. When starting nxterm example in nsh, I am
>> seeing
>> > the nxterm booting and setting the display, but when it should redirect
>> > stdout to nxterm, it doesn't. I am still in USB console. Looking the
>> code I
>> > see that nsh_consolemain function is called from nsh_usbconsole.c,
>> because
>> > of USB console set in KConfig. Later it is calling nsh_configstdio
>> > which
>> > duplicates stdio again and I think this is the reason for nxterm stdout
>> not
>> > working. How can I get around this problem?
>> >
>> > Thanks,
>> > Jernej
>> >
>>
>