No, it is the same board and config that worked before with NuttX 8.2
without such issues. Only several modifications same as was done for fmu-v5
to work with 10.0.0.
Serial consoles on PX4 boards work ok, no such issues, right?

ср, 11 нояб. 2020 г. в 14:14, David Sidrane <david.sidr...@nscdg.com>:

> Are you running any PX4IO drivers or RC  input?
>
> -----Original Message-----
> From: Oleg Evseev [mailto:ev.m...@gmail.com]
> Sent: Wednesday, November 11, 2020 3:09 AM
> To: dev@nuttx.apache.org
> Subject: Serial console strange behaviour
>
> Hi,
>
> Custom board stm32f7, PX4 based project - moved from NuttX 8.2 to 10.0.0.
> If serial dev console (CONFIG_USART6_SERIAL_CONSOLE=y) is used, it works:
> prints all corresponding output on boot, but then
>
> "nsh> " is shown only when I start typing in putty.
> "ls" command shows only the first output line. Other lines are shown only
> if I type at least one symbol.
> I tried with and without CONFIG_USART6_RXDMA - same result.
>
> USB CDC ACM console works OK.
>
> Any thoughts on what can cause such behavior?
>
> ---
> With best regards, Oleg
>

Reply via email to