Hi, in the beginning it is worth getting a green visa.

11.08.2021, 15:21, "Ivan Fedorenkov" <ivan.fedoren...@gmail.com>:
> Dear Ignite Devs,
>
> I would like to contribute a fix that addresses a bug associated with
> registration of user types by Ignite Java Thin Client. Could someone please
> review the code? https://github.com/apache/ignite/pull/9307
>
> Problem description: when Java Thin Client reestablishes connection to
> Ignite and invokes a Service API method with Externalizable input parameter
> server node may throw ClassNotFoundException and client marks the
> connection as broken and tries to open a new one.
>
> Root cause: Ignite server nodes may lose all the registered user types
> after restart if Ignite Working Dir gets deleted or cluster moves to
> another set of hosts. Clients, at the same time, believe that they have
> already registered their user types and they skip registration after
> reconnecting.
>
> Please note that this is my first PR into Ignite repo and I may easily miss
> some important details.
>
> Best regards,
> Ivan Fedorenkov

Reply via email to