Vladimir Steshin created IGNITE-13014:
-----------------------------------------

             Summary: Remove long, double checking of node availability. Fix 
hardcoded values.
                 Key: IGNITE-13014
                 URL: https://issues.apache.org/jira/browse/IGNITE-13014
             Project: Ignite
          Issue Type: Improvement
            Reporter: Vladimir Steshin
            Assignee: Vladimir Steshin


For the present, we have duplicated checking of node availability. This 
prolongs node failure detection and gives no additional benefits. There are 
mesh and hardcoded values in this routine.
Let's imagine node 2 doesn't answer any more. Node 1 becomes unable to ping 
node 2 and asks Node 3 to establish permanent connection instead of node 2. 
Despite node 2 has been already pinged within configured timeouts, node 3 try 
to connect to node 2 too. 
Disadvantages:
1)      Possible long detection of node failure up to 
ServerImpl.CON_CHECK_INTERVAL + 2 * IgniteConfiguretion.failureDetectionTimeout 
+ 300ms. See ‘WostCase.txt’

2)      Unexpected, not-configurable decision to check availability of previous 
node based on ‘2 * ServerImpl.CON_CHECK_INTERVAL‘:

// We got message from previous in less than double connection check interval.
boolean ok = rcvdTime + CON_CHECK_INTERVAL * 2 >= now; 

If ‘ok == true’ node 3 checks node 2.

3)      Double node checking brings several not-configurable hardcoded delays:
Node 3 checks node 2 with hardcoded timeout 100ms:
ServerImpl.isConnectionRefused():

sock.connect(addr, 100);

Checking availability of previous node considers any exception but 
ConnectionException (connection refused) as existing connection. Even a 
timeout. See ServerImpl.isConnectionRefused().



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to