Ondrej Rysavy created IGNITE-11337:
--------------------------------------

             Summary: Ignite .NET - Remote Assembly Loading problem when using 
Data Streamers
                 Key: IGNITE-11337
                 URL: https://issues.apache.org/jira/browse/IGNITE-11337
             Project: Ignite
          Issue Type: Bug
    Affects Versions: 2.7
         Environment: Apache Ignite 2.7.0 installed from NuGet, running on 
Windows 10.

Ignite server executed as:

{{...\.nuget\packages\apache.ignite\2.7.0\lib\net40>Apache.Ignite.exe}}

The test console program (.NET 4.6 target) attached.
            Reporter: Ondrej Rysavy
         Attachments: Program.cs

When using data streaming, the server raises "IgniteException: No matching type 
found for object [typeId=721826618, typeName=StreamingDemo.StringPairVisitor]".

StreamingDemo.StringPairVisitor implements IStreamReceiver interface (see the 
attached file).

{{}}Neither suggested solution works (remote assembly loading, -assembly 
argument, etc.)

The possible workaround is to execute some compute action prior to streaming. 
Then everything works as expected. 

In general, it seems that Streaming itself does not load the necessary assembly 
to locate the matching type implementing custom logic for stream processing.



--