https://issues.apache.org/jira/browse/HIVE-4123?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13731580#comment-13731580
]
Prasanth J commented on HIVE-4123:
----------------------------------
Following fixes were added to this patch
- Removed FIXMEs
- For determining the type of integer encoding (DIRECT/DIRECT_V2) used by
dictionaries, a new encoding type DICTIONARY_V2 is added. DICTIONARY_V2 uses
DIRECT_V2 encoding for dictionary data and length streams. In earlier patch,
there is no way to determined if dictionaries used DIRECT or DIRECT_V2
encoding. This patch addresses this issue. I am not sure if there is any other
way to determine this without adding new encoding type.
- addressed code review comment related to having if/then/else in flush()
method of RunLengthIntegerWriterV2
> The RLE encoding for ORC can be improved
> ----------------------------------------
>
> Key: HIVE-4123
> URL: https://issues.apache.org/jira/browse/HIVE-4123
> Project: Hive
> Issue Type: New Feature
> Components: File Formats
> Affects Versions: 0.12.0
> Reporter: Owen O'Malley
> Assignee: Prasanth J
> Labels: orcfile
> Fix For: 0.12.0
>
> Attachments: HIVE-4123.1.git.patch.txt, HIVE-4123.2.git.patch.txt,
> HIVE-4123.3.patch.txt, HIVE-4123.4.patch.txt, HIVE-4123.5.txt,
> ORC-Compression-Ratio-Comparison.xlsx
>
>
> The run length encoding of integers can be improved:
> * tighter bit packing
> * allow delta encoding
> * allow longer runs
--
This message is automatically generated by JIRA.