Hi,

Yes, it also sounds generally speaking good to me.

I'm just not sure whether we should make the existing `Counter` monotonic,
or introduce the new `MonotonicCounter`.
If we do the former, how would you propose Efrat to do that? Just
deprecating `Counter#dec` in let's say Flink 2.4,
will not make `Counter` monotonic. That will happen only once we drop
`Counter#dec` (in? 2.5? 2.6? 3.0?). Or am I
missing something?

Best,
Piotrek

czw., 2 lip 2026 o 23:26 Ryan van Huuksloot via dev <[email protected]>
napisał(a):

> Hi Efrat,
>
> Sorry for the delay.
>
> Overall this sounds good to me. We haven't encountered this too often but I
> do know what you are referring to; it's annoying to know if the counter was
> decremented versus reset.
>
> I'm not well versed in all of the touchpoints to give the best guidance but
> it does make sense and is a really nice quality of life improvement for
> observability.
>
> Ryan van Huuksloot
> Staff Engineer, Infrastructure | Streaming Platform
> [image: Shopify]
> <https://www.shopify.com/?utm_medium=salessignatures&utm_source=hs_email>
>
>
> On Thu, Jun 25, 2026 at 1:24 PM Efrat Levitan <[email protected]>
> wrote:
>
> > Hey Ryan,
> > Thank you for reading through the description.
> > I published the FLIP in hope it will provides a better understanding
> > of the proposal [1]
> >
> > > Is the issue you are trying to resolve that we don't know if a Counter
> > is monotonic?
> > Yes this is the main concern of the FLIP, distinguishing monotonicity
> > so backend systems can tell that there was integer overflow or system
> > restart during a given time and are able to smooth it out in graphs.
> > If Counter.dec was widely used in flink we were having a different
> > discussion, but since it was only historically introduced (Dropwizard
> > compatibility?) and never used within our codebase, I believe
> > declaring monotonicity is worth deprecating Counter.dec (+ providing
> > the UpDownCounter alternative)
> >
> > > Prometheus casts it to a Gauge because that code path hasn't been
> > upgraded in years
> > Prometheus' latest java client still throws[2] if you try to decrease
> > it. This is by design, and the reason flink counters are mapped to
> > prom gauges.
> > You didn't share more about the internal implementation but if it uses
> > prometheus counters, I'd assume negative deltas are ignored as in OTel
> > reporter today
> > This FLIP can actually pave the way for it to be contributed-
> > with true monotonicity, Flink counter will correctly map to prometheus
> > Counter (please check out the "proposed change" section of the FLIP)
> >
> > Let me know what you think.
> > Efrat
> >
> > [1] https://cwiki.apache.org/confluence/x/twDuGQ
> > [2]
> >
> https://github.com/prometheus/client_java/blob/main/prometheus-metrics-core/src/main/java/io/prometheus/metrics/core/metrics/Counter.java#L189
> >
> > On Mon, 22 Jun 2026 at 17:23, Ryan van Huuksloot via dev
> > <[email protected]> wrote:
> > >
> > > Hi Efrat,
> > >
> > > I'd like to clarify the intention of the FLIP, as it seems like we are
> > > introducing multiple issues.
> > >
> > > Is the issue you are trying to resolve that we don't know if a Counter
> is
> > > monotonic?
> > >
> > > After reading the links and the FLIP description, it sounds like we
> need
> > to
> > > fix the OTEL reporter. I don't immediately see any major reason to
> > overhaul
> > > the entire counter system. The current Counter can go up and down, but
> > the
> > > OTEL reporter didn't respect that.
> > >
> > > I also wanted to point out that Prometheus casts it to a Gauge because
> > that
> > > code path hasn't been upgraded in years. It should use the Native
> > Counters
> > > that now exist in Prometheus, we just haven't done the work to
> > > upgrade/migrate. We have an internal implementation to move Flink
> > Counters
> > > to Prometheus Native Counters.
> > >
> > > Is there something I am missing?
> > >
> > > Ryan van Huuksloot
> > > Staff Engineer, Infrastructure | Streaming Platform
> > > [image: Shopify]
> > > <
> https://www.shopify.com/?utm_medium=salessignatures&utm_source=hs_email
> > >
> > >
> > >
> > > On Mon, Jun 15, 2026 at 2:07 PM Efrat Levitan <[email protected]>
> > wrote:
> > >
> > > > Hi all,
> > > > I would like to start a discussion about how to differentiate
> > > > monotonic and non monotonic counters in flink metrics.
> > > >
> > > > Monotonic (ever-increasing) Counters can benefit from automatic reset
> > > > detection on the monitoring system side (when the value drops we can
> > > > safely assume the process was reset and synthetically adjust the
> > > > value)
> > > >
> > > > Historically, flink Counter can be decremented / incremented by a
> > > > non-positive value, but this has almost never been used intentionally
> > > > across the flink codebase, i.e if a counter got decremented this is
> > > > usually a bug [1].
> > > > So though system-emitted counters are effectively monotonic,
> exporters
> > > > must respect org.apache.flink.metrics.Counter contract and assume
> > > > non-monotonicity.
> > > >
> > > > I'd like to propose deprecating org.apache.flink.metrics.Counter#dec
> > > > in favor of a new UpDownCounter implementation. This matches modern
> > > > metric APIs like OTel, where the regular Counter is monotonic[2] and
> > > > an additional UpDownCounter supports[3] non-positive additions.
> > > >
> > > > While it seems to be the cleanest approach, we could still avoid the
> > > > deprecation by introducing a MonotonicCounter and have all flink
> > > > counters migrated, or expand the Counter interface to declare
> > > > monotonicity (based on the implementation).
> > > >
> > > > Recognising monotonicity will also align counters reporting across
> > > > monitoring systems. Today, for instance, Otel reporter drops[4]
> > > > non-incremental data points with a warning, while Prometheus reporter
> > > > casts[5] them as Gauges.
> > > >
> > > > I'm looking forward to your feedback
> > > > Efrat
> > > >
> > > > [1] https://issues.apache.org/jira/browse/FLINK-39892
> > > > [2]
> > > >
> >
> https://github.com/open-telemetry/opentelemetry-java/blob/main/api/all/src/main/java/io/opentelemetry/api/metrics/LongCounter.java#L40
> > > > [3]
> > > >
> >
> https://github.com/open-telemetry/opentelemetry-java/blob/main/api/all/src/main/java/io/opentelemetry/api/metrics/LongUpDownCounter.java
> > > > [4] https://issues.apache.org/jira/browse/FLINK-39893
> > > > [5]
> > > >
> >
> https://github.com/apache/flink/blob/master/flink-metrics/flink-metrics-prometheus/src/main/java/org/apache/flink/metrics/prometheus/AbstractPrometheusReporter.java#L177-L184
> > > >
> >
>

Reply via email to