Efrat Levitan created FLINK-39893:
-------------------------------------

             Summary: Respect non-monotonic counter accumulation in 
openTelemetry reporter
                 Key: FLINK-39893
                 URL: https://issues.apache.org/jira/browse/FLINK-39893
             Project: Flink
          Issue Type: Bug
          Components: Runtime / Metrics
    Affects Versions: 2.2.1
            Reporter: Efrat Levitan


Otel reporter 
[drops|https://github.com/apache/flink/blob/master/flink-metrics/flink-metrics-otel/src/main/java/org/apache/flink/metrics/otel/OpenTelemetryMetricAdapter.java#L66-L73]
 the non-incremental datapoint with a warn, which is incorrect because flink 
{{Counter}} does not guarantee monotonicity (i.e 
[supports|https://github.com/apache/flink/blob/master/flink-metrics/flink-metrics-core/src/main/java/org/apache/flink/metrics/Counter.java#L35-L45]
 {{{}dec{}}}, or {{inc}} by a negative)

 



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to