Dongming WU created FLINK-28914:
-----------------------------------
Summary: Could not find any factories that implement
Key: FLINK-28914
URL: https://issues.apache.org/jira/browse/FLINK-28914
Project: Flink
Issue Type: Bug
Components: Table SQL / Gateway
Affects Versions: 1.16.0
Reporter: Dongming WU
Fix For: 1.16.0
2022-08-11 11:09:53,135 ERROR org.apache.flink.table.gateway.SqlGateway
[] - Failed to start the endpoints.
org.apache.flink.table.api.ValidationException: Could not find any factories
that implement
'org.apache.flink.table.gateway.api.endpoint.SqlGatewayEndpointFactory' in the
classpath.
-----------------------------------------------------
I packaged Flink-Master and tried to start sql-gateway, but some problems arise.
I found tow problem with Factory under resources of flink-sql-gateway module.
META-INF.services should not be a folder name, ti should be ...
/META-INF/services/...
The
`` org.apache.flink.table.gateway.rest.SqlGatewayRestEndpointFactory `` in the
org.apache.flink.table.factories.Factory file should be
`` org.apache.flink.table.gateway.rest.util.SqlGatewayRestEndpointFactory `` .
--