fanrui created FLINK-27251:
------------------------------
Summary: Solve the problem that upstream Task cannot be switched
to Unaligned Checkpoint
Key: FLINK-27251
URL: https://issues.apache.org/jira/browse/FLINK-27251
Project: Flink
Issue Type: Improvement
Components: Runtime / Checkpointing
Affects Versions: 1.14.0, 1.15.0
Reporter: fanrui
Fix For: 1.16.0
After FLINK-23041, the downstream task can be switched UC when {_}currentTime -
triggerTime > timeout{_}. But the downstream task still needs wait for all
barriers of upstream.
If the back pressure is serve, the downstream task cannot receive all barrier
within CP timeout, causes CP to fail.
Can we support upstream Task switching from Aligned to UC? It means that when
the barrier cannot be sent from the output buffer to the downstream task within
the
[execution.checkpointing.aligned-checkpoint-timeout|https://nightlies.apache.org/flink/flink-docs-release-1.14/docs/deployment/config/#execution-checkpointing-aligned-checkpoint-timeout],
the upstream task switches to UC and takes a snapshot of the data before the
barrier in the output buffer.
Hi [~akalashnikov] , please help take a look in your free time, thanks a lot.
--
This message was sent by Atlassian Jira