Fabian Paul created FLINK-24382:
-----------------------------------

             Summary: RecordsOut metric for sinks is inaccurate
                 Key: FLINK-24382
                 URL: https://issues.apache.org/jira/browse/FLINK-24382
             Project: Flink
          Issue Type: Improvement
          Components: Connectors / Common, Runtime / Metrics
    Affects Versions: 1.14.0, 1.15.0
            Reporter: Fabian Paul


Currently, the metric is computed on the operator level and it is assumed that 
every record flowing into the sink also generates one outgoing record.

This is often not reasonable because the sinks can transform incoming records 
into multiple outgoing records, thus the metric should be implemented by the 
sink implementors and not be reasoned by the framework.



--