Maximilian Michels created FLINK-16573: ------------------------------------------
Summary: Kinesis consumer does not properly shutdown RecordFetcher threads Key: FLINK-16573 URL: https://issues.apache.org/jira/browse/FLINK-16573 Project: Flink Issue Type: Bug Components: Connectors / Kinesis Affects Versions: 1.10.0, 1.9.2, 1.8.3 Reporter: Maximilian Michels Assignee: Maximilian Michels Fix For: 1.11.0 The threads may not shut down correctly because they do not check for the running flag in the inner loops. The threads also do not get interrupted because they are not connected to the main task thread. These threads keep lingering around after the job has shut down: {noformat} Thread 23168: (state = BLOCKED) - java.lang.Object.wait(long) @bci=0 (Compiled frame; information may be imprecise) - org.apache.flink.streaming.connectors.kinesis.util.RecordEmitter.emitRecords() @bci=140, line=209 (Compiled frame) - org.apache.flink.streaming.connectors.kinesis.util.RecordEmitter.run() @bci=18, line=177 (Interpreted frame) - java.lang.Thread.run() @bci=11, line=748 (Compiled frame) {noformat} -- This message was sent by Atlassian Jira (v8.3.4#803005)