Jingsong Lee created FLINK-12611: ------------------------------------ Summary: Make time indicator nullable in blink Key: FLINK-12611 URL: https://issues.apache.org/jira/browse/FLINK-12611 Project: Flink Issue Type: Improvement Components: Table SQL / Planner Reporter: Jingsong Lee Assignee: Jingsong Lee
SQL: select max(rowtime), count(a) from T There will be a AssertionError: type mismatch: aggCall type: TIMESTAMP(3) NOT NULL inferred type: TIMESTAMP(3) Agg type checking is done before TimeIndicator materializes. So there is a exception. And before introducing nullable of LogicalType, we should modify this to avoid more potential TypeCheck problems. -- This message was sent by Atlassian JIRA (v7.6.3#76005)