Tom Goong created FLINK-11742: --------------------------------- Summary: Push metrics t0 Pushgateway without "instance" Key: FLINK-11742 URL: https://issues.apache.org/jira/browse/FLINK-11742 Project: Flink Issue Type: Bug Components: Metrics Reporter: Tom Goong Assignee: Tom Goong Attachments: image-2019-02-25-17-16-28-618.png, image-2019-02-25-17-16-59-034.png
According to the official article, [https://prometheus.io/docs/concepts/jobs_instances/] [https://github.com/prometheus/pushgateway] when sending a metric to Prometheus Pushgateway, you need to give an "instance" message. In actual use, after there is no "instance", Prometheus stores metrics with problems, metrics are not continuous, and a lot of data is lost. After adding instance, it returns to normal. !image-2019-02-25-17-16-28-618.png! !image-2019-02-25-17-16-59-034.png! -- This message was sent by Atlassian JIRA (v7.6.3#76005)