Tzu-Li (Gordon) Tai created FLINK-7728: ------------------------------------------
Summary: StatusWatermarkValve has different min watermark advancement behavior depending on the ordering inputs become idle Key: FLINK-7728 URL: https://issues.apache.org/jira/browse/FLINK-7728 Project: Flink Issue Type: Bug Components: DataStream API Affects Versions: 1.3.2, 1.2.1, 1.4.0 Reporter: Tzu-Li (Gordon) Tai Assignee: Tzu-Li (Gordon) Tai Priority: Blocker Fix For: 1.2.2, 1.4.0, 1.3.3 Currently, once all inputs of a {{StatusWatermarkValve}} becomes idle, we only emit the {{StreamStatus.IDLE}} marker, and check nothing else. This makes the watermark advancement behavior inconsistent in the case that all inputs become idle, depending on the order that they become idle. Consider the following setup: {code} Channel #1: Watermark 10, ACTIVE Channel #2: Watermark 5, ACTIVE Channel #3: Watermark 5, ACTIVE {code} If the channels become IDLE with the order #2 -> #3 -> #1, watermark 10 will be emitted as the new min watermark once both #2 and #3 becomes idle. On the other hand, if the order is #1 -> #2 -> #3, watermark 10 will not be emitted. -- This message was sent by Atlassian JIRA (v6.4.14#64029)