I think we are still doing changes for which this is relevant. Also I cannot 
really see a benefit in delaying this because the whole discussion will apply 
in exactly the same way to 1.5.

> Am 17.08.2017 um 13:29 schrieb Greg Hogan <c...@greghogan.com>:
> 
> There’s an argument for delaying this change to 1.5 since the feature freeze 
> is two weeks away. There is little time to realize benefits from removing 
> this code.
> 
> "The reason for that is that there is a lot of code mapping between the 
> completely different legacy format (1.1.x, not re-scalable) and the 
> key-group-oriented format (1.2.x onwards, re-scalable). It would greatly help 
> the development of state and checkpointing features to drop that old code.”
> 
> Greg
> 
> 
>> On Aug 17, 2017, at 5:36 AM, Stefan Richter <s.rich...@data-artisans.com> 
>> wrote:
>> 
>> One more comment about the consequences of this PR, as pointed out in the 
>> comments on Github: this will also break direct compatibility for the CEP 
>> library between Flink 1.2 and 1.4. There is still a way to migrate via Flink 
>> 1.3: Flink 1.1/2 -> savepoint -> Flink 1.3 -> savepoint -> Flink 1.4.
>> 
>>> Am 16.08.2017 um 17:31 schrieb Stefan Richter <s.rich...@data-artisans.com>:
>>> 
>>> Hi,
>>> 
>>> after there have been no objections since a long time, I took the next step 
>>> and created a PR that implements this change in commit 
>>> 95e44099784c9deaf2ca422b8dfc11c3d67d7f82 of 
>>> https://github.com/apache/flink/pull/4550 
>>> <https://github.com/apache/flink/pull/4550> . Announcing this here as a 
>>> last opportunity for further discussions. FYI, this will decrease the code 
>>> base by almost 12K LOC. 
>>> 
>>> Best,
>>> Stefan
>>> 
>>> 
>>>> Am 02.08.2017 um 15:26 schrieb Kostas Kloudas <k.klou...@data-artisans.com 
>>>> <mailto:k.klou...@data-artisans.com>>:
>>>> 
>>>> +1
>>>> 
>>>>> On Aug 2, 2017, at 3:16 PM, Till Rohrmann <trohrm...@apache.org 
>>>>> <mailto:trohrm...@apache.org>> wrote:
>>>>> 
>>>>> +1
>>>>> 
>>>>> On Wed, Aug 2, 2017 at 9:12 AM, Stefan Richter 
>>>>> <s.rich...@data-artisans.com <mailto:s.rich...@data-artisans.com>>
>>>>> wrote:
>>>>> 
>>>>>> +1
>>>>>> 
>>>>>> Am 28.07.2017 um 16:03 schrieb Stephan Ewen <se...@apache.org 
>>>>>> <mailto:se...@apache.org>>:
>>>>>> 
>>>>>> Seems like no one raised a concern so far about dropping the savepoint
>>>>>> format compatibility for 1.1 in 1.4.
>>>>>> 
>>>>>> Leaving this thread open for some more days, but from the sentiment, it
>>>>>> seems like we should go ahead?
>>>>>> 
>>>>>> On Wed, Jul 12, 2017 at 4:43 PM, Stephan Ewen <se...@apache.org 
>>>>>> <mailto:se...@apache.org>> wrote:
>>>>>> 
>>>>>>> Hi users!
>>>>>>> 
>>>>>>> Flink currently maintains backwards compatibility for savepoint formats,
>>>>>>> which means that savepoints taken with Flink version 1.1.x and 1.2.x 
>>>>>>> can be
>>>>>>> resumed in Flink 1.3.x
>>>>>>> 
>>>>>>> We are discussing how many versions back to support. The proposition is
>>>>>>> the following:
>>>>>>> 
>>>>>>> *   Suggestion: Flink 1.4.0 will be able to resume savepoints taken with
>>>>>>> version 1.3.x and 1.2.x, but not savepoints from version 1.1.x and 
>>>>>>> 1.0.x*
>>>>>>> 
>>>>>>> 
>>>>>>> The reason for that is that there is a lot of code mapping between the
>>>>>>> completely different legacy format (1.1.x, not re-scalable) and the
>>>>>>> key-group-oriented format (1.2.x onwards, re-scalable). It would greatly
>>>>>>> help the development of state and checkpointing features to drop that 
>>>>>>> old
>>>>>>> code.
>>>>>>> 
>>>>>>> Please let us know if you have concerns about that.
>>>>>>> 
>>>>>>> Best,
>>>>>>> Stephan
>>>>>>> 
>>>>>>> 
>>>>>> 
>>>>>> 
>>>> 
>>> 
>> 
> 

Reply via email to