Fabian Hueske created FLINK-7239:
------------------------------------

             Summary: GroupWindow and OverWindow aggregates do not check 
correctly for updating input
                 Key: FLINK-7239
                 URL: https://issues.apache.org/jira/browse/FLINK-7239
             Project: Flink
          Issue Type: Bug
          Components: Table API & SQL
    Affects Versions: 1.3.1, 1.4.0
            Reporter: Fabian Hueske


The streaming table operators for group-window and over-window aggregates do 
only support append-only input, i.e., no updates.

However, the {{DataStreamGroupWindowAggregate}} {{DataStreamOverAggregate}} 
RelNodes do only check that the input does not have retraction messages which 
is only one possible encoding of updates.

We should fix the RelNodes to check if the input is append-only using the 
{{UpdatingPlanChecker}} similar to {{DataStreamWindowJoin}}.



--
This message was sent by Atlassian JIRA
(v6.4.14#64029)