Kostas Kloudas created FLINK-4651: ------------------------------------- Summary: Re-register processing time timers at the WindowOperator upon recovery. Key: FLINK-4651 URL: https://issues.apache.org/jira/browse/FLINK-4651 Project: Flink Issue Type: Bug Components: Windowing Operators Reporter: Kostas Kloudas Assignee: Kostas Kloudas Fix For: 1.1.3
Currently the {{{WindowOperator}}} checkpoints the processing time timers, but upon recovery it does not re-registers them with the {{{TimeServiceProvider}}}. To actually reprocess them it relies on another element that will come and register a new timer for a future point in time. Although this is a realistic assumption in long running jobs, we can remove this assumption by re-registering the restored timers with the {{{TimeServiceProvider}}} in the {{{open()}}} method of the {{{WindowOperator}}}. -- This message was sent by Atlassian JIRA (v6.3.4#6332)