Hi all, I'm using OVS-2.8.0 + DPDK-17.05-rc1, with 2 pf and 1 vf port under mlx5 pmd driver, like this:
$ sudo /usr/local/share/openvswitch/scripts/dpdk_nic_bind --status > Network devices using DPDK-compatible driver > ============================================ > <none> > Network devices using kernel driver > =================================== > ... > 0000:03:00.0 'MT27640 Family' if=eth4 drv=mlx5_core unused=igb_uio > 0000:03:00.1 'MT27640 Family' if=eth5 drv=mlx5_core unused=igb_uio > 0000:03:00.2 'MT27641 Family' if=enp3s0f2 drv=mlx5_core unused=igb_uio > *Active* > ... > Other network devices > ===================== > <none> Then I start ovs-vswitchd follow these steps: > mkdir -p /usr/local/etc/openvswitch > mkdir -p /usr/local/var/run/openvswitch > [root@dpdk ~]# rm /usr/local/etc/openvswitch/conf.db > [root@dpdk ~]# ovsdb-tool create /usr/local/etc/openvswitch/conf.db > /usr/local/share/openvswitch/vswitch.ovsschema > [root@dpdk ~]# ovsdb-server /usr/local/etc/openvswitch/conf.db \ > -vconsole:emer -vsyslog:err -vfile:info \ > --remote=punix:/usr/local/var/run/openvswitch/db.sock \ > --private-key=db:Open_vSwitch,SSL,private_key \ > --certificate=db:Open_vSwitch,SSL,certificate \ > --bootstrap-ca-cert=db:Open_vSwitch,SSL,ca_cert --no-chdir \ > --log-file=/usr/local/var/log/openvswitch/ovsdb-server.log \ > --pidfile=/usr/local/var/run/openvswitch/ovsdb-server.pid \ > --detach --monitor > [root@dpdk ~]# ovs-vsctl --no-wait init > [root@dpdk ~]# ovs-vsctl --no-wait set Open_vSwitch . > other_config:dpdk-init=true > [root@dpdk ~]# ovs-vsctl --no-wait set Open_vSwitch . > other_config:dpdk-socket-mem="1024,0" > [root@dpdk ~]# ovs-vsctl --no-wait set Open_vSwitch . > other_config:pmd-cpu-mask=0x04 > [root@dpdk ~]# ovs-vswitchd unix:/usr/local/var/run/openvswitch/db.sock \ > -vconsole:emer -vsyslog:err -vfile:info --mlockall --no-chdir \ > --log-file=/usr/local/var/log/openvswitch/ovs-vswitchd.log \ > --pidfile=/usr/local/var/run/openvswitch/ovs-vswitchd.pid \ > --detach --monitor Then I add br0 and dpdk0 port follow these steps: > ovs-vsctl add-br br0 -- set bridge br0 datapath_type=netdev > ovs-vsctl add-port br0 dpdk0 -- set Interface dpdk0 type=dpdk > options:dpdk-devargs=0000:03:00.0 After that, I got error in ovs-vswitchd.log like this: > 2018-03-29T02:44:11.913Z|00071|memory|INFO|handlers:22 ports:1 > revalidators:8 rules:5 > 2018-03-29T02:45:18.658Z|00072|netdev_dpdk|WARN|Error attaching device > '0000:03:00.0' to DPDK > 2018-03-29T02:45:18.658Z|00073|netdev|WARN|dpdk0: could not set > configuration (Invalid argument) Deep into code, I found this is caused by these code in rte_ethdev.c: > int > rte_eth_dev_attach(const char *devargs, uint16_t *port_id) > { > int ret = -1; > int current = rte_eth_dev_count(); > ... > /* if nothing happened, there is a bug here, since some driver told us > * it did attach a device, but did not create a port. > */ > if (current == rte_eth_dev_count()) { > ret = -1; > goto err; > } > ... > } Which is the nb_ports returned by rte_eth_dev_count() keeps the same. I think this is mlx5 driver probe port count and add into nb_ports while starting ovs-vswitchd, not adding port by command `ovs-vsctl add port br0 ...`. Refer to "mlx5_pci_probe" -> "rte_eth_dev_allocate" -> "eth_dev_get". So is this a bug or I should use some other way to add port into bridge under mlx5 driver? Or is this bug fixed in some version? Or how to fix this bug? Thank you~