Hi Burakov, When using vfio-pci on host both VF and PF interfaces works fine with dpdk i.e. I don't see DMAR fault messages anymore. However, when I attach a VF interface to a VM and start DPDK with vfio-pci inside VM I still see DMAR fault messages on host. Both host and VM are booted with 'intel-iommu=on' on GRUB. Ping from VM with DPDK/vfio-pci doesn't work (I think it's expected because of DMAR faults), however, when VF interface uses ixgbevf driver ping works.
Following are some details /*****************On VM***************/ dpdk-devbind -s Network devices using DPDK-compatible driver ============================================ 0000:00:07.0 '82599 Ethernet Controller Virtual Function' drv=vfio-pci unused=ixgbevf Network devices using kernel driver =================================== 0000:03:00.0 'Device 1041' if=eth0 drv=virtio-pci unused=vfio-pci *Active* 0000:04:00.0 'Device 1041' if=eth1 drv=virtio-pci unused=vfio-pci 0000:05:00.0 'Device 1041' if=eth2 drv=virtio-pci unused=vfio-pci Other network devices ===================== <none> Crypto devices using DPDK-compatible driver =========================================== <none> Crypto devices using kernel driver ================================== <none> Other crypto devices ==================== <none> 00:07.0 Ethernet controller: Intel Corporation 82599 Ethernet Controller Virtual Function (rev 01) Subsystem: Intel Corporation 82599 Ethernet Controller Virtual Function Control: I/O- Mem+ BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx+ Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- INTx- Region 0: Memory at fda00000 (64-bit, prefetchable) [size=16K] Region 3: Memory at fda04000 (64-bit, prefetchable) [size=16K] Capabilities: [70] MSI-X: Enable+ Count=3 Masked- Vector table: BAR=3 offset=00000000 PBA: BAR=3 offset=00002000 Capabilities: [a0] Express (v1) Root Complex Integrated Endpoint, MSI 00 DevCap: MaxPayload 128 bytes, PhantFunc 0 ExtTag- RBE- DevCtl: Report errors: Correctable- Non-Fatal- Fatal- Unsupported- RlxdOrd- ExtTag- PhantFunc- AuxPwr- NoSnoop- MaxPayload 128 bytes, MaxReadReq 128 bytes DevSta: CorrErr- UncorrErr- FatalErr- UnsuppReq- AuxPwr- TransPend- Capabilities: [100 v1] Advanced Error Reporting UESta: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UEMsk: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- UESvrt: DLP- SDES- TLP- FCP- CmpltTO- CmpltAbrt- UnxCmplt- RxOF- MalfTLP- ECRC- UnsupReq- ACSViol- CESta: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- CEMsk: RxErr- BadTLP- BadDLLP- Rollover- Timeout- NonFatalErr- AERCap: First Error Pointer: 00, GenCap- CGenEn- ChkCap- ChkEn- Kernel driver in use: vfio-pci Kernel modules: ixgbevf /***************on Host*************/ dmesg | grep DMAR ... [ 978.268143] DMAR: DRHD: handling fault status reg 2 [ 978.268147] DMAR: [DMA Read] *Request device [04:10.0]* fault addr 33a128000 [fault reason 06] PTE Read access is not set [ 1286.677726] DMAR: DRHD: handling fault status reg 102 [ 1286.677730] DMAR: [DMA Read] Request device [04:10.0] fault addr fb663000 [fault reason 06] PTE Read access is not set [ 1676.436145] DMAR: DRHD: handling fault status reg 202 [ 1676.436149] DMAR: [DMA Read] Request device [04:10.0] fault addr 33a128000 [fault reason 06] PTE Read access is not set [ 1734.433649] DMAR: DRHD: handling fault status reg 302 [ 1734.433652] DMAR: [DMA Read] Request device [04:10.0] fault addr 33a128000 [fault reason 06] PTE Read access is not set [ 2324.428938] DMAR: DRHD: handling fault status reg 402 [ 2324.428942] DMAR: [DMA Read] Request device [04:10.0] fault addr 7770c000 [fault reason 06] PTE Read access is not set [ 2388.553640] DMAR: DRHD: handling fault status reg 502 [ 2388.553643] DMAR: [DMA Read] *Request device [04:10.0]* fault addr 33a128000 [fault reason 06] PTE Read access is not set VM is started with qemu-system-x86_64 -enable-kvm -M q35,accel=kvm,kernel-irqchip=split -object iothread,id=iothread0 -device intel-iommu,intremap=on,device-iotlb=on,caching-mode=on -cpu host -daemonize -m 16G -smp 14 -uuid 0fc91c66-f0b1-11e7-acf4-525400123456 -name 212748-sriov-ravi-smac-alpha-SMAC10 -device ioh3420,id=root.1,chassis=1 -device ioh3420,id=root.2,chassis=2 -netdev tap,vhost=on,queues=2,ifname=vn-vn2_1_,downscript=no,id=vn-vn2_1_,script=no -device ioh3420,id=root.3,chassis=3 -device virtio-net-pci,netdev=vn-vn2_1_,bus=root.3,ats=on,mq=on,vectors=6,mac=DE:AD:02:88:10:37,id=vn-vn2_1__dev -netdev tap,vhost=on,queues=2,ifname=vn-vn92_1_,downscript=no,id=vn-vn92_1_,script=no -device ioh3420,id=root.4,chassis=4 -device virtio-net-pci,mac=DE:AD:02:88:10:38,netdev=vn-vn92_1_,bus=root.4,ats=on,mq=on,vectors=6,id=vn-vn92_1__dev -netdev tap,vhost=on,queues=2,ifname=vn-vn93_1_,downscript=no,id=vn-vn93_1_,script=no -device ioh3420,id=root.5,chassis=5 -device virtio-net-pci,mac=DE:AD:02:88:10:39,netdev=vn-vn93_1_,bus=root.5,ats=on,mq=on,vectors=6,id=vn-vn93_1__dev -vnc :16,websocket=15916 -qmp tcp:127.0.0.1:12001,server,nowait -chardev socket,id=charmonitor,path=/tmp/mon.12001,server,nowait -mon chardev=charmonitor,id=monitor -cdrom /var/venom/cloud_init/0fc91c66-f0b1-11e7-acf4-525400123456.iso -*device vfio-pci,host=04:10.0* -drive file=/var/venom/instance_repo/test.img,if=none,id=drive-virtio-disk0,format=raw,aio=native,cache=none -balloon none -device virtio-blk-pci,scsi=off,iothread=iothread0,drive=drive-virtio-disk0,id=virtio-disk0,bus=root.1,ats=on,bootindex=1 Thanks. On Thu, Jan 25, 2018 at 2:49 AM, Burakov, Anatoly <anatoly.bura...@intel.com > wrote: > On 24-Jan-18 7:13 PM, Ravi Kerur wrote: > >> Hi Burakov, Thank you. I will try with vfio-pci driver. I am assuming it >> will work for both PF and VF interfaces since I am using both in my setup? >> >> Thanks. >> > > Yes, it should work for both PF and VF devices. > > >> On Wed, Jan 24, 2018 at 2:31 AM, Burakov, Anatoly < >> anatoly.bura...@intel.com <mailto:anatoly.bura...@intel.com>> wrote: >> >> On 23-Jan-18 5:25 PM, Ravi Kerur wrote: >> >> Hi, >> >> I am running into an issue when DPDK is started with iommu on >> via GRUB >> command. Problem is not seen with regular kernel driver, error >> messages >> show when DPDK is started and happens for both PF and VF >> interfaces. >> >> I am using DPDK 17.05 so the patch proposed in the following link >> is >> available >> http://dpdk.org/ml/archives/dev/2017-February/057048.html >> <http://dpdk.org/ml/archives/dev/2017-February/057048.html> >> >> Workaround is to use "iommu=pt" but I want iommu enabled in my >> setup. I >> checked BIOS for reserved memory(DMA RMRR for IXGBE) didn't get >> any details >> on it. >> >> Kindly let me know how to resolve this issue. >> >> Following are the details >> >> (1) Linux kernel 4.9 >> (2) DPDK 17.05 >> >> (3) IXGBE details >> ethtool -i enp4s0f0 (PF driver) >> driver: ixgbe >> version: 5.3.3 >> firmware-version: 0x800007b8, 1.1018.0 >> bus-info: 0000:04:00.0 >> supports-statistics: yes >> supports-test: yes >> supports-eeprom-access: yes >> supports-register-dump: yes >> supports-priv-flags: yes >> >> ethtool -i enp4s16f2 (VF driver) >> driver: ixgbevf >> version: 4.3.2 >> firmware-version: >> bus-info: 0000:04:10.2 >> supports-statistics: yes >> supports-test: yes >> supports-eeprom-access: no >> supports-register-dump: yes >> supports-priv-flags: no >> >> Bus info Device Class Description >> ========================================================= >> pci@0000:01:00.0 ens11f0 network 82599ES 10-Gigabit >> SFI/SFP+ >> Network Connection >> pci@0000:01:00.1 ens11f1 network 82599ES 10-Gigabit >> SFI/SFP+ >> Network Connection >> pci@0000:04:00.0 enp4s0f0 network 82599ES 10-Gigabit >> SFI/SFP+ >> Network Connection >> pci@0000:04:00.1 enp4s0f1 network 82599ES 10-Gigabit >> SFI/SFP+ >> Network Connection >> pci@0000:04:10.0 enp4s16 network Illegal Vendor ID >> pci@0000:04:10.2 enp4s16f2 network Illegal Vendor ID >> >> (4) DPDK bind interfaces >> >> # dpdk-devbind -s >> >> Network devices using DPDK-compatible driver >> ============================================ >> 0000:01:00.0 '82599ES 10-Gigabit SFI/SFP+ Network Connection 10fb' >> drv=igb_uio unused=vfio-pci >> 0000:04:10.2 '82599 Ethernet Controller Virtual Function 10ed' >> drv=igb_uio >> unused=vfio-pci >> >> Network devices using kernel driver >> =================================== >> 0000:01:00.1 '82599ES 10-Gigabit SFI/SFP+ Network Connection 10fb' >> if=ens11f1 drv=ixgbe unused=igb_uio,vfio-pci >> 0000:04:00.0 '82599ES 10-Gigabit SFI/SFP+ Network Connection 10fb' >> if=enp4s0f0 drv=ixgbe unused=igb_uio,vfio-pci >> 0000:04:00.1 '82599ES 10-Gigabit SFI/SFP+ Network Connection 10fb' >> if=enp4s0f1 drv=ixgbe unused=igb_uio,vfio-pci >> 0000:04:10.0 '82599 Ethernet Controller Virtual Function 10ed' >> if=enp4s16 >> drv=ixgbevf unused=igb_uio,vfio-pci >> 0000:06:00.0 'I210 Gigabit Network Connection 1533' if=eno1 >> drv=igb >> unused=igb_uio,vfio-pci *Active* >> >> Other Network devices >> ===================== >> <none> >> >> ... >> >> (5) Kernel dmesg >> >> # dmesg | grep -e DMAR >> [ 0.000000] ACPI: DMAR 0x000000007999BAD0 0000E0 (v01 ALASKA >> A M I >> 00000001 INTL 20091013) >> [ 0.000000] DMAR: IOMMU enabled >> [ 0.518747] DMAR: Host address width 46 >> [ 0.526616] DMAR: DRHD base: 0x000000fbffc000 flags: 0x0 >> [ 0.537447] DMAR: dmar0: reg_base_addr fbffc000 ver 1:0 cap >> d2078c106f0466 ecap f020df >> [ 0.553620] DMAR: DRHD base: 0x000000c7ffc000 flags: 0x1 >> [ 0.564445] DMAR: dmar1: reg_base_addr c7ffc000 ver 1:0 cap >> d2078c106f0466 ecap f020df >> [ 0.580611] DMAR: RMRR base: 0x0000007bbc6000 end: >> 0x0000007bbd4fff >> [ 0.593344] DMAR: ATSR flags: 0x0 >> [ 0.600178] DMAR: RHSA base: 0x000000c7ffc000 proximity >> domain: 0x0 >> [ 0.612905] DMAR: RHSA base: 0x000000fbffc000 proximity >> domain: 0x1 >> [ 0.625632] DMAR-IR: IOAPIC id 3 under DRHD base 0xfbffc000 >> IOMMU 0 >> [ 0.638522] DMAR-IR: IOAPIC id 1 under DRHD base 0xc7ffc000 >> IOMMU 1 >> [ 0.651426] DMAR-IR: IOAPIC id 2 under DRHD base 0xc7ffc000 >> IOMMU 1 >> [ 0.664324] DMAR-IR: HPET id 0 under DRHD base 0xc7ffc000 >> [ 0.675326] DMAR-IR: Queued invalidation will be enabled to >> support >> x2apic and Intr-remapping. >> [ 0.693805] DMAR-IR: Enabled IRQ remapping in x2apic mode >> [ 9.395170] DMAR: dmar1: Using Queued invalidation >> [ 9.405011] DMAR: Setting RMRR: >> [ 9.412006] DMAR: Setting identity map for device 0000:00:1d.0 >> [0x7bbc6000 - 0x7bbd4fff] >> [ 9.428569] DMAR: Prepare 0-16MiB unity mapping for LPC >> [ 9.439712] DMAR: Setting identity map for device >> 0000:00:1f.0 [0x0 - >> 0xffffff] >> [ 9.454684] DMAR: Intel(R) Virtualization Technology for >> Directed I/O >> [ 287.023068] DMAR: DRHD: handling fault status reg 2 >> [ 287.023073] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 18a260a000 [fault reason 06] PTE Read access is not set >> [ 287.023180] DMAR: DRHD: handling fault status reg 102 >> [ 287.023183] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 18a3010000 [fault reason 06] PTE Read access is not set >> [ 287.038250] DMAR: DRHD: handling fault status reg 202 >> [ 287.038252] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 18a3010000 [fault reason 06] PTE Read access is not set >> [ 288.170165] DMAR: DRHD: handling fault status reg 302 >> [ 288.170170] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 1890754000 [fault reason 06] PTE Read access is not set >> [ 288.694496] DMAR: DRHD: handling fault status reg 402 >> [ 288.694499] DMAR: [DMA Read] Request device [04:10.2] fault >> addr >> 189069c000 [fault reason 06] PTE Read access is not set >> [ 289.927113] DMAR: DRHD: handling fault status reg 502 >> [ 289.927116] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 1890754000 [fault reason 06] PTE Read access is not set >> [ 290.174275] DMAR: DRHD: handling fault status reg 602 >> [ 290.174279] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 1890754000 [fault reason 06] PTE Read access is not set >> [ 292.174247] DMAR: DRHD: handling fault status reg 702 >> [ 292.174251] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 1890754000 [fault reason 06] PTE Read access is not set >> [ 294.174227] DMAR: DRHD: handling fault status reg 2 >> [ 294.174230] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 1890754000 [fault reason 06] PTE Read access is not set >> [ 296.174216] DMAR: DRHD: handling fault status reg 102 >> [ 296.174219] DMAR: [DMA Read] Request device [01:00.0] fault >> addr >> 1890754000 [fault reason 06] PTE Read access is not set >> [r...@infradev-comp006.naw02.infradev.viasat.io >> <mailto:r...@infradev-comp006.naw02.infradev.viasat.io> ~] >> # >> >> Thanks. >> >> >> Hi Ravi, >> >> The "iommu=pt" workaround applies only when you want to use igb_uio >> driver. VFIO driver is able to fully utilize IOMMU without the need >> for pass-through mode. From your log i can see that some devices are >> bound to igb_uio while others are bound to vfio-pci. Just bind all >> of the devices you want to use with DPDK to vfio-pci and these >> errors should go away. >> >> -- Thanks, >> Anatoly >> >> >> > > -- > Thanks, > Anatoly >