Please disregard the Community Lab DTS failure just reported on this
patchseries. I need to reconfigure the testbed and rerun the test.

On Sun, May 4, 2025 at 1:24 AM Gregory Etelson <getel...@nvidia.com> wrote:

> METER flow action is not supported in MLX5 HWS mode.
> Application must use METER_MARK flow action.
>
> The patch removes METER action from HWS code.
>
> Fixes: 48fbb0e93d06 ("net/mlx5: support flow meter mark indirect action
> with HWS")
> Signed-off-by: Gregory Etelson <getel...@nvidia.com>
> Acked-by: Dariusz Sosnowski <dsosnow...@nvidia.com>
> ---
>  drivers/net/mlx5/mlx5_flow_hw.c    |  85 -----
>  drivers/net/mlx5/mlx5_flow_meter.c | 552 -----------------------------
>  2 files changed, 637 deletions(-)
>
> diff --git a/drivers/net/mlx5/mlx5_flow_hw.c
> b/drivers/net/mlx5/mlx5_flow_hw.c
> index 20d38ce414..1f192c1937 100644
> --- a/drivers/net/mlx5/mlx5_flow_hw.c
> +++ b/drivers/net/mlx5/mlx5_flow_hw.c
> @@ -1784,35 +1784,6 @@ flow_hw_represented_port_compile(struct rte_eth_dev
> *dev,
>         return 0;
>  }
>
> -static __rte_always_inline int
> -flow_hw_meter_compile(struct rte_eth_dev *dev,
> -                     const struct mlx5_flow_template_table_cfg *cfg,
> -                     uint16_t aso_mtr_pos,
> -                     uint16_t jump_pos,
> -                     const struct rte_flow_action *action,
> -                     struct mlx5_hw_actions *acts,
> -                     struct rte_flow_error *error)
> -{
> -       struct mlx5_priv *priv = dev->data->dev_private;
> -       struct mlx5_aso_mtr *aso_mtr;
> -       const struct rte_flow_action_meter *meter = action->conf;
> -       uint32_t group = cfg->attr.flow_attr.group;
> -
> -       aso_mtr = mlx5_aso_meter_by_idx(priv, meter->mtr_id);
> -       acts->rule_acts[aso_mtr_pos].action = priv->mtr_bulk.action;
> -       acts->rule_acts[aso_mtr_pos].aso_meter.offset = aso_mtr->offset;
> -       acts->jump = flow_hw_jump_action_register
> -               (dev, cfg, aso_mtr->fm.group, error);
> -       if (!acts->jump)
> -               return -ENOMEM;
> -       acts->rule_acts[jump_pos].action = (!!group) ?
> -                                   acts->jump->hws_action :
> -                                   acts->jump->root_action;
> -       if (mlx5_aso_mtr_wait(priv, aso_mtr, true))
> -               return -ENOMEM;
> -       return 0;
> -}
> -
>  static __rte_always_inline int
>  flow_hw_cnt_compile(struct rte_eth_dev *dev, uint32_t  start_pos,
>                       struct mlx5_hw_actions *acts)
> @@ -2534,7 +2505,6 @@ __flow_hw_translate_actions_template(struct
> rte_eth_dev *dev,
>         bool reformat_used = false;
>         bool recom_used = false;
>         unsigned int of_vlan_offset;
> -       uint16_t jump_pos;
>         uint32_t ct_idx;
>         int ret, err;
>         uint32_t target_grp = 0;
> @@ -2802,27 +2772,6 @@ __flow_hw_translate_actions_template(struct
> rte_eth_dev *dev,
>                                          masks, acts, src_pos, dr_pos,
> &sub_error))
>                                 goto err;
>                         break;
> -               case RTE_FLOW_ACTION_TYPE_METER:
> -                       /*
> -                        * METER action is compiled to 2 DR actions -
> ASO_METER and FT.
> -                        * Calculated DR offset is stored only for
> ASO_METER and FT
> -                        * is assumed to be the next action.
> -                        */
> -                       jump_pos = dr_pos + 1;
> -                       if (actions->conf && masks->conf &&
> -                           ((const struct rte_flow_action_meter *)
> -                            masks->conf)->mtr_id) {
> -                               err = flow_hw_meter_compile(dev, cfg,
> -                                                           dr_pos,
> jump_pos, actions, acts,
> -                                                           &sub_error);
> -                               if (err)
> -                                       goto err;
> -                       } else if (__flow_hw_act_data_general_append(priv,
> acts,
> -
> actions->type,
> -
> src_pos,
> -
> dr_pos))
> -                               goto err;
> -                       break;
>                 case RTE_FLOW_ACTION_TYPE_AGE:
>                         ret = flow_hw_translate_group(dev, cfg,
> attr->group,
>                                                 &target_grp, &sub_error);
> @@ -3510,7 +3459,6 @@ flow_hw_actions_construct(struct rte_eth_dev *dev,
>         const struct rte_flow_action_ipv6_ext_push *ipv6_push;
>         const struct rte_flow_item *enc_item = NULL;
>         const struct rte_flow_action_ethdev *port_action = NULL;
> -       const struct rte_flow_action_meter *meter = NULL;
>         const struct rte_flow_action_age *age = NULL;
>         const struct rte_flow_action_nat64 *nat64_c = NULL;
>         struct rte_flow_attr attr = {
> @@ -3683,28 +3631,6 @@ flow_hw_actions_construct(struct rte_eth_dev *dev,
>                                                 rule_acts +
> act_data->action_dst,
>                                                 act_data->shared_meter.id
> );
>                         break;
> -               case RTE_FLOW_ACTION_TYPE_METER:
> -                       meter = action->conf;
> -                       mtr_id = meter->mtr_id;
> -                       aso_mtr = mlx5_aso_meter_by_idx(priv, mtr_id);
> -                       rule_acts[act_data->action_dst].action =
> -                               priv->mtr_bulk.action;
> -                       rule_acts[act_data->action_dst].aso_meter.offset =
> -
>  aso_mtr->offset;
> -                       jump = flow_hw_jump_action_register
> -                               (dev, &table->cfg, aso_mtr->fm.group,
> NULL);
> -                       if (!jump)
> -                               goto error;
> -                       MLX5_ASSERT
> -                               (!rule_acts[act_data->action_dst +
> 1].action);
> -                       rule_acts[act_data->action_dst + 1].action =
> -                                       (!!attr.group) ? jump->hws_action :
> -                                                        jump->root_action;
> -                       flow->jump = jump;
> -                       flow->flags |= MLX5_FLOW_HW_FLOW_FLAG_FATE_JUMP;
> -                       if (mlx5_aso_mtr_wait(priv, aso_mtr, true))
> -                               goto error;
> -                       break;
>                 case RTE_FLOW_ACTION_TYPE_AGE:
>                         aux = mlx5_flow_hw_aux(dev->data->port_id, flow);
>                         age = action->conf;
> @@ -7334,10 +7260,6 @@ mlx5_flow_hw_actions_validate(struct rte_eth_dev
> *dev,
>                         }
>                         action_flags |=
> MLX5_FLOW_ACTION_IPV6_ROUTING_REMOVE;
>                         break;
> -               case RTE_FLOW_ACTION_TYPE_METER:
> -                       /* TODO: Validation logic */
> -                       action_flags |= MLX5_FLOW_ACTION_METER;
> -                       break;
>                 case RTE_FLOW_ACTION_TYPE_METER_MARK:
>                         ret = flow_hw_validate_action_meter_mark(dev,
> action, false, error);
>                         if (ret < 0)
> @@ -7665,13 +7587,6 @@ flow_hw_parse_flow_actions_to_dr_actions(struct
> rte_eth_dev *dev,
>                                 action_types[mhdr_off] = type;
>                         }
>                         break;
> -               case RTE_FLOW_ACTION_TYPE_METER:
> -                       at->dr_off[i] = curr_off;
> -                       action_types[curr_off++] =
> MLX5DR_ACTION_TYP_ASO_METER;
> -                       if (curr_off >= MLX5_HW_MAX_ACTS)
> -                               goto err_actions_num;
> -                       action_types[curr_off++] = MLX5DR_ACTION_TYP_TBL;
> -                       break;
>                 case RTE_FLOW_ACTION_TYPE_OF_PUSH_VLAN:
>                         type =
> mlx5_hw_dr_action_types[at->actions[i].type];
>                         at->dr_off[i] = curr_off;
> diff --git a/drivers/net/mlx5/mlx5_flow_meter.c
> b/drivers/net/mlx5/mlx5_flow_meter.c
> index dab3c4bf77..cd6a804593 100644
> --- a/drivers/net/mlx5/mlx5_flow_meter.c
> +++ b/drivers/net/mlx5/mlx5_flow_meter.c
> @@ -1166,49 +1166,6 @@ mlx5_flow_meter_policy_validate(struct rte_eth_dev
> *dev,
>         return 0;
>  }
>
> -#if defined(HAVE_MLX5_HWS_SUPPORT)
> -/**
> - * Callback to check MTR policy action validate for HWS
> - *
> - * @param[in] dev
> - *   Pointer to Ethernet device.
> - * @param[in] actions
> - *   Pointer to meter policy action detail.
> - * @param[out] error
> - *   Pointer to the error structure.
> - *
> - * @return
> - *   0 on success, a negative errno value otherwise and rte_errno is set.
> - */
> -static int
> -mlx5_flow_meter_policy_hws_validate(struct rte_eth_dev *dev,
> -       struct rte_mtr_meter_policy_params *policy,
> -       struct rte_mtr_error *error)
> -{
> -       struct mlx5_priv *priv = dev->data->dev_private;
> -       const struct rte_flow_actions_template_attr attr = {
> -               .transfer = priv->sh->config.dv_esw_en ? 1 : 0 };
> -       int ret;
> -       int i;
> -
> -       if (mlx5_hws_active(dev) && !mlx5_hw_ctx_validate(dev, NULL))
> -               return -rte_mtr_error_set(error, EINVAL,
> -                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED,
> NULL,
> -                                         "non-template flow engine was
> not configured");
> -       if (!priv->mtr_en || !priv->sh->meter_aso_en)
> -               return -rte_mtr_error_set(error, ENOTSUP,
> -                               RTE_MTR_ERROR_TYPE_METER_POLICY,
> -                               NULL, "meter policy unsupported.");
> -       for (i = 0; i < RTE_COLORS; i++) {
> -               ret = mlx5_flow_actions_validate(dev, &attr,
> policy->actions[i],
> -                                                policy->actions[i], NULL);
> -               if (ret)
> -                       return ret;
> -       }
> -       return 0;
> -}
> -#endif
> -
>  static int
>  __mlx5_flow_meter_policy_delete(struct rte_eth_dev *dev,
>                         uint32_t policy_id,
> @@ -1540,334 +1497,6 @@ mlx5_flow_meter_policy_get(struct rte_eth_dev *dev,
>                                                               &policy_idx);
>  }
>
> -#if defined(HAVE_MLX5_HWS_SUPPORT)
> -/**
> - * Callback to delete MTR policy for HWS.
> - *
> - * @param[in] dev
> - *   Pointer to Ethernet device.
> - * @param[in] policy_id
> - *   Meter policy id.
> - * @param[out] error
> - *   Pointer to the error structure.
> - *
> - * @return
> - *   0 on success, a negative errno value otherwise and rte_errno is set.
> - */
> -static int
> -mlx5_flow_meter_policy_hws_delete(struct rte_eth_dev *dev,
> -                         uint32_t policy_id,
> -                         struct rte_mtr_error *error)
> -{
> -       struct mlx5_priv *priv = dev->data->dev_private;
> -       struct mlx5_flow_meter_policy *mtr_policy;
> -       uint32_t i, j;
> -       uint32_t nb_flows = 0;
> -       int ret;
> -       struct rte_flow_op_attr op_attr = { .postpone = 1 };
> -       struct rte_flow_op_result result[RTE_COLORS * MLX5_MTR_DOMAIN_MAX];
> -
> -       if (!priv->mtr_policy_arr)
> -               return mlx5_flow_meter_policy_delete(dev, policy_id,
> error);
> -       /* Meter policy must exist. */
> -       mtr_policy = mlx5_flow_meter_policy_find(dev, policy_id, NULL);
> -       if (!mtr_policy->initialized)
> -               return -rte_mtr_error_set(error, ENOENT,
> -                       RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL,
> -                       "Meter policy does not exists.");
> -       /* Check policy is unused. */
> -       if (mtr_policy->ref_cnt)
> -               return -rte_mtr_error_set(error, EBUSY,
> -
>  RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
> -                                         NULL, "Meter policy is in use.");
> -       rte_spinlock_lock(&priv->hw_ctrl_lock);
> -       for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) {
> -               for (j = 0; j < RTE_COLORS; j++) {
> -                       if (mtr_policy->hws_flow_rule[i][j]) {
> -                               ret =
> rte_flow_async_destroy(dev->data->port_id,
> -                                       CTRL_QUEUE_ID(priv), &op_attr,
> -                                       mtr_policy->hws_flow_rule[i][j],
> -                                       NULL, NULL);
> -                               if (ret < 0)
> -                                       continue;
> -                               nb_flows++;
> -                       }
> -               }
> -       }
> -       ret = rte_flow_push(dev->data->port_id, CTRL_QUEUE_ID(priv), NULL);
> -       while (nb_flows && (ret >= 0)) {
> -               ret = rte_flow_pull(dev->data->port_id,
> -                                       CTRL_QUEUE_ID(priv), result,
> -                                       nb_flows, NULL);
> -               nb_flows -= ret;
> -       }
> -       for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) {
> -               if (mtr_policy->hws_flow_table[i])
> -                       rte_flow_template_table_destroy(dev->data->port_id,
> -                                mtr_policy->hws_flow_table[i], NULL);
> -       }
> -       for (i = 0; i < RTE_COLORS; i++) {
> -               if (mtr_policy->hws_act_templ[i])
> -
>  rte_flow_actions_template_destroy(dev->data->port_id,
> -                                mtr_policy->hws_act_templ[i], NULL);
> -       }
> -       if (mtr_policy->hws_item_templ)
> -               rte_flow_pattern_template_destroy(dev->data->port_id,
> -                               mtr_policy->hws_item_templ, NULL);
> -       rte_spinlock_unlock(&priv->hw_ctrl_lock);
> -       memset(mtr_policy, 0, sizeof(struct mlx5_flow_meter_policy));
> -       return 0;
> -}
> -
> -/**
> - * Callback to add MTR policy for HWS.
> - *
> - * @param[in] dev
> - *   Pointer to Ethernet device.
> - * @param[out] policy_id
> - *   Pointer to policy id
> - * @param[in] actions
> - *   Pointer to meter policy action detail.
> - * @param[out] error
> - *   Pointer to the error structure.
> - *
> - * @return
> - *   0 on success, a negative errno value otherwise and rte_errno is set.
> - */
> -static int
> -mlx5_flow_meter_policy_hws_add(struct rte_eth_dev *dev,
> -                       uint32_t policy_id,
> -                       struct rte_mtr_meter_policy_params *policy,
> -                       struct rte_mtr_error *error)
> -{
> -       struct mlx5_priv *priv = dev->data->dev_private;
> -       struct mlx5_flow_meter_policy *mtr_policy = NULL;
> -       const struct rte_flow_action *act;
> -       const struct rte_flow_action_meter *mtr;
> -       struct mlx5_flow_meter_info *fm;
> -       struct mlx5_flow_meter_policy *plc;
> -       uint8_t domain_color = MLX5_MTR_ALL_DOMAIN_BIT;
> -       bool is_rss = false;
> -       bool is_hierarchy = false;
> -       int i, j;
> -       uint32_t nb_colors = 0;
> -       uint32_t nb_flows = 0;
> -       int color;
> -       int ret;
> -       struct rte_flow_pattern_template_attr pta = {0};
> -       struct rte_flow_actions_template_attr ata = {0};
> -       struct rte_flow_template_table_attr ta = { {0}, 0 };
> -       struct rte_flow_op_attr op_attr = { .postpone = 1 };
> -       struct rte_flow_op_result result[RTE_COLORS * MLX5_MTR_DOMAIN_MAX];
> -       const uint32_t color_mask = (UINT32_C(1) << MLX5_MTR_COLOR_BITS) -
> 1;
> -       int color_reg_c_idx = mlx5_flow_get_reg_id(dev, MLX5_MTR_COLOR,
> -                                                  0, NULL);
> -       struct rte_flow_item_tag tag_spec = {
> -               .data = 0,
> -               .index = color_reg_c_idx
> -       };
> -       struct rte_flow_item_tag tag_mask = {
> -               .data = color_mask,
> -               .index = 0xff};
> -       struct rte_flow_item pattern[] = {
> -               [0] = {
> -                       .type = (enum rte_flow_item_type)
> -                               MLX5_RTE_FLOW_ITEM_TYPE_TAG,
> -                       .spec = &tag_spec,
> -                       .mask = &tag_mask,
> -               },
> -               [1] = { .type = RTE_FLOW_ITEM_TYPE_END }
> -       };
> -
> -       if (mlx5_hws_active(dev) && !mlx5_hw_ctx_validate(dev, NULL))
> -               return -rte_mtr_error_set(error, EINVAL,
> -                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED,
> NULL,
> -                                         "non-template flow engine was
> not configured");
> -       if (!priv->mtr_policy_arr)
> -               return mlx5_flow_meter_policy_add(dev, policy_id, policy,
> error);
> -       mtr_policy = mlx5_flow_meter_policy_find(dev, policy_id, NULL);
> -       if (mtr_policy->initialized)
> -               return -rte_mtr_error_set(error, EEXIST,
> -                       RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
> -                       NULL, "Meter policy already exists.");
> -       if (!policy ||
> -           (!policy->actions[RTE_COLOR_RED] &&
> -           !policy->actions[RTE_COLOR_YELLOW] &&
> -           !policy->actions[RTE_COLOR_GREEN]))
> -               return -rte_mtr_error_set(error, EINVAL,
> -                                         RTE_MTR_ERROR_TYPE_METER_POLICY,
> -                                         NULL, "Meter policy actions are
> not valid.");
> -       if (policy->actions[RTE_COLOR_RED] == RTE_FLOW_ACTION_TYPE_END)
> -               mtr_policy->skip_r = 1;
> -       if (policy->actions[RTE_COLOR_YELLOW] == RTE_FLOW_ACTION_TYPE_END)
> -               mtr_policy->skip_y = 1;
> -       if (policy->actions[RTE_COLOR_GREEN] == RTE_FLOW_ACTION_TYPE_END)
> -               mtr_policy->skip_g = 1;
> -       if (mtr_policy->skip_r && mtr_policy->skip_y && mtr_policy->skip_g)
> -               return -rte_mtr_error_set(error, ENOTSUP,
> -
>  RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
> -                                         NULL, "Meter policy actions are
> empty.");
> -       for (i = 0; i < RTE_COLORS; i++) {
> -               act = policy->actions[i];
> -               while (act && act->type != RTE_FLOW_ACTION_TYPE_END) {
> -                       switch (act->type) {
> -                       case RTE_FLOW_ACTION_TYPE_PORT_ID:
> -                               /* fall-through. */
> -                       case RTE_FLOW_ACTION_TYPE_REPRESENTED_PORT:
> -                               domain_color &=
> ~(MLX5_MTR_DOMAIN_INGRESS_BIT |
> -
>  MLX5_MTR_DOMAIN_EGRESS_BIT);
> -                               break;
> -                       case RTE_FLOW_ACTION_TYPE_RSS:
> -                               is_rss = true;
> -                               /* fall-through. */
> -                       case RTE_FLOW_ACTION_TYPE_QUEUE:
> -                               domain_color &=
> ~(MLX5_MTR_DOMAIN_EGRESS_BIT |
> -
>  MLX5_MTR_DOMAIN_TRANSFER_BIT);
> -                               break;
> -                       case RTE_FLOW_ACTION_TYPE_METER:
> -                               is_hierarchy = true;
> -                               mtr = act->conf;
> -                               fm = mlx5_flow_meter_find(priv,
> -                                                         mtr->mtr_id,
> NULL);
> -                               if (!fm)
> -                                       return -rte_mtr_error_set(error,
> EINVAL,
> -                                               RTE_MTR_ERROR_TYPE_MTR_ID,
> NULL,
> -                                               "Meter not found in meter
> hierarchy.");
> -                               plc = mlx5_flow_meter_policy_find(dev,
> -
>  fm->policy_id,
> -                                                                 NULL);
> -                               MLX5_ASSERT(plc);
> -                               domain_color &= MLX5_MTR_ALL_DOMAIN_BIT &
> -                                       (plc->ingress <<
> -                                        MLX5_MTR_DOMAIN_INGRESS);
> -                               domain_color &= MLX5_MTR_ALL_DOMAIN_BIT &
> -                                       (plc->egress <<
> -                                        MLX5_MTR_DOMAIN_EGRESS);
> -                               domain_color &= MLX5_MTR_ALL_DOMAIN_BIT &
> -                                       (plc->transfer <<
> -                                        MLX5_MTR_DOMAIN_TRANSFER);
> -                               break;
> -                       default:
> -                               break;
> -                       }
> -                       act++;
> -               }
> -       }
> -       if (priv->sh->config.dv_esw_en)
> -               domain_color &= ~(MLX5_MTR_DOMAIN_EGRESS_BIT |
> -                                 MLX5_MTR_DOMAIN_TRANSFER_BIT);
> -       else
> -               domain_color &= ~MLX5_MTR_DOMAIN_TRANSFER_BIT;
> -       if (!domain_color)
> -               return -rte_mtr_error_set(error, ENOTSUP,
> -
>  RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
> -                                         NULL, "Meter policy domains are
> conflicting.");
> -       mtr_policy->is_rss = is_rss;
> -       mtr_policy->ingress = !!(domain_color &
> MLX5_MTR_DOMAIN_INGRESS_BIT);
> -       pta.ingress = mtr_policy->ingress;
> -       mtr_policy->egress = !!(domain_color & MLX5_MTR_DOMAIN_EGRESS_BIT);
> -       pta.egress = mtr_policy->egress;
> -       mtr_policy->transfer = !!(domain_color &
> MLX5_MTR_DOMAIN_TRANSFER_BIT);
> -       pta.transfer = mtr_policy->transfer;
> -       mtr_policy->group = MLX5_FLOW_TABLE_HWS_POLICY - policy_id;
> -       mtr_policy->is_hierarchy = is_hierarchy;
> -       mtr_policy->initialized = 1;
> -       rte_spinlock_lock(&priv->hw_ctrl_lock);
> -       mtr_policy->hws_item_templ =
> -               rte_flow_pattern_template_create(dev->data->port_id,
> -                                                &pta, pattern, NULL);
> -       if (!mtr_policy->hws_item_templ)
> -               goto policy_add_err;
> -       for (i = 0; i < RTE_COLORS; i++) {
> -               if (mtr_policy->skip_g && i == RTE_COLOR_GREEN)
> -                       continue;
> -               if (mtr_policy->skip_y && i == RTE_COLOR_YELLOW)
> -                       continue;
> -               if (mtr_policy->skip_r && i == RTE_COLOR_RED)
> -                       continue;
> -               mtr_policy->hws_act_templ[nb_colors] =
> -
>  rte_flow_actions_template_create(dev->data->port_id,
> -                                               &ata, policy->actions[i],
> -                                               policy->actions[i], NULL);
> -               if (!mtr_policy->hws_act_templ[nb_colors])
> -                       goto policy_add_err;
> -               nb_colors++;
> -       }
> -       for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) {
> -               memset(&ta, 0, sizeof(ta));
> -               ta.nb_flows = RTE_COLORS;
> -               ta.flow_attr.group = mtr_policy->group;
> -               if (i == MLX5_MTR_DOMAIN_INGRESS) {
> -                       if (!mtr_policy->ingress)
> -                               continue;
> -                       ta.flow_attr.ingress = 1;
> -               } else if (i == MLX5_MTR_DOMAIN_EGRESS) {
> -                       if (!mtr_policy->egress)
> -                               continue;
> -                       ta.flow_attr.egress = 1;
> -               } else if (i == MLX5_MTR_DOMAIN_TRANSFER) {
> -                       if (!mtr_policy->transfer)
> -                               continue;
> -                       ta.flow_attr.transfer = 1;
> -               }
> -               mtr_policy->hws_flow_table[i] =
> -                       rte_flow_template_table_create(dev->data->port_id,
> -                                       &ta, &mtr_policy->hws_item_templ,
> 1,
> -                                       mtr_policy->hws_act_templ,
> nb_colors,
> -                                       NULL);
> -               if (!mtr_policy->hws_flow_table[i])
> -                       goto policy_add_err;
> -               nb_colors = 0;
> -               for (j = 0; j < RTE_COLORS; j++) {
> -                       if (mtr_policy->skip_g && j == RTE_COLOR_GREEN)
> -                               continue;
> -                       if (mtr_policy->skip_y && j == RTE_COLOR_YELLOW)
> -                               continue;
> -                       if (mtr_policy->skip_r && j == RTE_COLOR_RED)
> -                               continue;
> -                       color = rte_col_2_mlx5_col((enum rte_color)j);
> -                       tag_spec.data = color;
> -                       mtr_policy->hws_flow_rule[i][j] =
> -                               rte_flow_async_create(dev->data->port_id,
> -                                       CTRL_QUEUE_ID(priv), &op_attr,
> -                                       mtr_policy->hws_flow_table[i],
> -                                       pattern, 0, policy->actions[j],
> -                                       nb_colors, NULL, NULL);
> -                       if (!mtr_policy->hws_flow_rule[i][j])
> -                               goto policy_add_err;
> -                       nb_colors++;
> -                       nb_flows++;
> -               }
> -               ret = rte_flow_push(dev->data->port_id,
> -                                   CTRL_QUEUE_ID(priv), NULL);
> -               if (ret < 0)
> -                       goto policy_add_err;
> -               while (nb_flows) {
> -                       ret = rte_flow_pull(dev->data->port_id,
> -                                           CTRL_QUEUE_ID(priv), result,
> -                                           nb_flows, NULL);
> -                       if (ret < 0)
> -                               goto policy_add_err;
> -                       for (j = 0; j < ret; j++) {
> -                               if (result[j].status == RTE_FLOW_OP_ERROR)
> -                                       goto policy_add_err;
> -                       }
> -                       nb_flows -= ret;
> -               }
> -       }
> -       rte_spinlock_unlock(&priv->hw_ctrl_lock);
> -       return 0;
> -policy_add_err:
> -       rte_spinlock_unlock(&priv->hw_ctrl_lock);
> -       ret = mlx5_flow_meter_policy_hws_delete(dev, policy_id, error);
> -       memset(mtr_policy, 0, sizeof(struct mlx5_flow_meter_policy));
> -       if (ret)
> -               return ret;
> -       return -rte_mtr_error_set(error, ENOTSUP,
> -                                 RTE_MTR_ERROR_TYPE_UNSPECIFIED,
> -                                 NULL, "Failed to create meter policy.");
> -}
> -#endif
>  /**
>   * Check meter validation.
>   *
> @@ -2239,105 +1868,6 @@ mlx5_flow_meter_create(struct rte_eth_dev *dev,
> uint32_t meter_id,
>                 NULL, "Failed to create devx meter.");
>  }
>
> -#if defined(HAVE_MLX5_HWS_SUPPORT)
> -/**
> - * Create meter rules.
> - *
> - * @param[in] dev
> - *   Pointer to Ethernet device.
> - * @param[in] meter_id
> - *   Meter id.
> - * @param[in] params
> - *   Pointer to rte meter parameters.
> - * @param[in] shared
> - *   Meter shared with other flow or not.
> - * @param[out] error
> - *   Pointer to rte meter error structure.
> - *
> - * @return
> - *   0 on success, a negative errno value otherwise and rte_errno is set.
> - */
> -static int
> -mlx5_flow_meter_hws_create(struct rte_eth_dev *dev, uint32_t meter_id,
> -                      struct rte_mtr_params *params, int shared,
> -                      struct rte_mtr_error *error)
> -{
> -       struct mlx5_priv *priv = dev->data->dev_private;
> -       struct mlx5_flow_meter_profile *profile;
> -       struct mlx5_flow_meter_info *fm;
> -       struct mlx5_flow_meter_policy *policy = NULL;
> -       struct mlx5_aso_mtr *aso_mtr;
> -       struct mlx5_hw_q_job *job;
> -       int ret;
> -
> -       if (mlx5_hws_active(dev) && !mlx5_hw_ctx_validate(dev, NULL))
> -               return -rte_mtr_error_set(error, EINVAL,
> -                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED,
> NULL,
> -                                         "non-template flow engine was
> not configured");
> -       if (!priv->mtr_profile_arr ||
> -           !priv->mtr_policy_arr ||
> -           !priv->mtr_bulk.aso)
> -               return -rte_mtr_error_set(error, ENOTSUP,
> -                       RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
> -                       "Meter bulk array is not allocated.");
> -       /* Meter profile must exist. */
> -       profile = mlx5_flow_meter_profile_find(priv,
> params->meter_profile_id);
> -       if (!profile->initialized)
> -               return -rte_mtr_error_set(error, ENOENT,
> -                       RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
> -                       NULL, "Meter profile id not valid.");
> -       /* Meter policy must exist. */
> -       policy = mlx5_flow_meter_policy_find(dev,
> -                       params->meter_policy_id, NULL);
> -       if (!policy->initialized)
> -               return -rte_mtr_error_set(error, ENOENT,
> -                       RTE_MTR_ERROR_TYPE_METER_POLICY_ID,
> -                       NULL, "Meter policy id not valid.");
> -       /* Meter ID must be valid. */
> -       if (meter_id >= priv->mtr_config.nb_meters)
> -               return -rte_mtr_error_set(error, EINVAL,
> -                       RTE_MTR_ERROR_TYPE_MTR_ID,
> -                       NULL, "Meter id not valid.");
> -       /* Find ASO object. */
> -       aso_mtr = mlx5_aso_meter_by_idx(priv, meter_id);
> -       fm = &aso_mtr->fm;
> -       if (fm->initialized)
> -               return -rte_mtr_error_set(error, ENOENT,
> -                                         RTE_MTR_ERROR_TYPE_MTR_ID,
> -                                         NULL, "Meter object already
> exists.");
> -       /* Fill the flow meter parameters. */
> -       fm->meter_id = meter_id;
> -       fm->policy_id = params->meter_policy_id;
> -       fm->profile = profile;
> -       fm->meter_offset = meter_id;
> -       fm->group = policy->group;
> -       /* Add to the flow meter list. */
> -       fm->active_state = 1; /* Config meter starts as active. */
> -       fm->is_enable = params->meter_enable;
> -       fm->shared = !!shared;
> -       fm->initialized = 1;
> -       /* Update ASO flow meter by wqe. */
> -       job = mlx5_flow_action_job_init(priv, MLX5_HW_INV_QUEUE, NULL,
> NULL,
> -                                       NULL, MLX5_HW_Q_JOB_TYPE_CREATE,
> NULL);
> -       if (!job)
> -               return -rte_mtr_error_set(error, ENOMEM,
> -                                         RTE_MTR_ERROR_TYPE_MTR_ID,
> -                                         NULL, "No job context.");
> -       ret = mlx5_aso_meter_update_by_wqe(priv, MLX5_HW_INV_QUEUE,
> aso_mtr,
> -                                          &priv->mtr_bulk, job, true);
> -       if (ret) {
> -               flow_hw_job_put(priv, job, CTRL_QUEUE_ID(priv));
> -               return -rte_mtr_error_set(error, ENOTSUP,
> -                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED,
> -                                         NULL, "Failed to create devx
> meter.");
> -       }
> -       fm->active_state = params->meter_enable;
> -       rte_atomic_fetch_add_explicit(&fm->profile->ref_cnt, 1,
> rte_memory_order_relaxed);
> -       rte_atomic_fetch_add_explicit(&policy->ref_cnt, 1,
> rte_memory_order_relaxed);
> -       return 0;
> -}
> -#endif
> -
>  static int
>  mlx5_flow_meter_params_flush(struct rte_eth_dev *dev,
>                         struct mlx5_flow_meter_info *fm,
> @@ -2444,58 +1974,6 @@ mlx5_flow_meter_destroy(struct rte_eth_dev *dev,
> uint32_t meter_id,
>         return 0;
>  }
>
> -/**
> - * Destroy meter rules.
> - *
> - * @param[in] dev
> - *   Pointer to Ethernet device.
> - * @param[in] meter_id
> - *   Meter id.
> - * @param[out] error
> - *   Pointer to rte meter error structure.
> - *
> - * @return
> - *   0 on success, a negative errno value otherwise and rte_errno is set.
> - */
> -static int
> -mlx5_flow_meter_hws_destroy(struct rte_eth_dev *dev, uint32_t meter_id,
> -                       struct rte_mtr_error *error)
> -{
> -       struct mlx5_priv *priv = dev->data->dev_private;
> -       struct mlx5_aso_mtr *aso_mtr;
> -       struct mlx5_flow_meter_info *fm;
> -       struct mlx5_flow_meter_policy *policy;
> -
> -       if (!priv->mtr_profile_arr ||
> -           !priv->mtr_policy_arr ||
> -           !priv->mtr_bulk.aso)
> -               return -rte_mtr_error_set(error, ENOTSUP,
> -                       RTE_MTR_ERROR_TYPE_METER_POLICY, NULL,
> -                       "Meter bulk array is not allocated.");
> -       /* Find ASO object. */
> -       aso_mtr = mlx5_aso_meter_by_idx(priv, meter_id);
> -       fm = &aso_mtr->fm;
> -       if (!fm->initialized)
> -               return -rte_mtr_error_set(error, ENOENT,
> -                                         RTE_MTR_ERROR_TYPE_MTR_ID,
> -                                         NULL, "Meter object id not
> valid.");
> -       /* Meter object must not have any owner. */
> -       if (fm->ref_cnt > 0)
> -               return -rte_mtr_error_set(error, EBUSY,
> -                                         RTE_MTR_ERROR_TYPE_UNSPECIFIED,
> -                                         NULL, "Meter object is being
> used.");
> -       /* Destroy the meter profile. */
> -       rte_atomic_fetch_sub_explicit(&fm->profile->ref_cnt,
> -                                               1,
> rte_memory_order_relaxed);
> -       /* Destroy the meter policy. */
> -       policy = mlx5_flow_meter_policy_find(dev,
> -                       fm->policy_id, NULL);
> -       rte_atomic_fetch_sub_explicit(&policy->ref_cnt,
> -                                               1,
> rte_memory_order_relaxed);
> -       memset(fm, 0, sizeof(struct mlx5_flow_meter_info));
> -       return 0;
> -}
> -
>  /**
>   * Modify meter state.
>   *
> @@ -2835,14 +2313,6 @@ static const struct rte_mtr_ops
> mlx5_flow_mtr_hws_ops = {
>         .meter_profile_add = mlx5_flow_meter_profile_hws_add,
>         .meter_profile_delete = mlx5_flow_meter_profile_hws_delete,
>         .meter_profile_get = mlx5_flow_meter_profile_get,
> -       .meter_policy_validate = mlx5_flow_meter_policy_hws_validate,
> -       .meter_policy_add = mlx5_flow_meter_policy_hws_add,
> -       .meter_policy_delete = mlx5_flow_meter_policy_hws_delete,
> -       .meter_policy_get = mlx5_flow_meter_policy_get,
> -       .create = mlx5_flow_meter_hws_create,
> -       .destroy = mlx5_flow_meter_hws_destroy,
> -       .meter_enable = mlx5_flow_meter_enable,
> -       .meter_disable = mlx5_flow_meter_disable,
>         .meter_profile_update = mlx5_flow_meter_profile_update,
>         .meter_dscp_table_update = NULL,
>         .stats_update = NULL,
> @@ -3286,14 +2756,6 @@ mlx5_flow_meter_flush(struct rte_eth_dev *dev,
> struct rte_mtr_error *error)
>                                 NULL, "MTR object meter profile invalid.");
>                 }
>         }
> -       if (priv->mtr_bulk.aso) {
> -               for (i = 0; i < priv->mtr_config.nb_meters; i++) {
> -                       aso_mtr = mlx5_aso_meter_by_idx(priv, i);
> -                       fm = &aso_mtr->fm;
> -                       if (fm->initialized)
> -                               mlx5_flow_meter_hws_destroy(dev, i, error);
> -               }
> -       }
>         if (priv->policy_idx_tbl) {
>                 MLX5_L3T_FOREACH(priv->policy_idx_tbl, i, entry) {
>                         policy_idx = *(uint32_t *)entry;
> @@ -3319,20 +2781,6 @@ mlx5_flow_meter_flush(struct rte_eth_dev *dev,
> struct rte_mtr_error *error)
>                 mlx5_l3t_destroy(priv->policy_idx_tbl);
>                 priv->policy_idx_tbl = NULL;
>         }
> -#if defined(HAVE_MLX5_HWS_SUPPORT)
> -       if (priv->mtr_policy_arr) {
> -               struct mlx5_flow_meter_policy *policy;
> -
> -               for (i = 0; i < priv->mtr_config.nb_meter_policies; i++) {
> -                       policy = mlx5_flow_meter_policy_find(dev, i,
> -                                                            &policy_idx);
> -                       if (policy->initialized) {
> -                               mlx5_flow_meter_policy_hws_delete(dev, i,
> -                                                                 error);
> -                       }
> -               }
> -       }
> -#endif
>         if (priv->mtr_profile_tbl) {
>                 MLX5_L3T_FOREACH(priv->mtr_profile_tbl, i, entry) {
>                         fmp = entry;
> --
> 2.48.1
>
>

Reply via email to