On Tue, 18 Feb 2025 19:31:56 +0800
Huisong Li <lihuis...@huawei.com> wrote:

> Testpmd doesn't modify the Rx/Tx queue number of all ports after attach a
> new device. The root cause is that "port config all rxq <value>" would
> check if all ports are stopped and the status of this port is still in
> 'RTE_PORT_HANDLING'. This status is changed to 'RTE_PORT_STOPPED' in
> setup_attached_port() when start port.
> 
> In addition, this new port needs to be initialized in advance because these
> information are depanded on many commands. Otherwise other commands like
> "port config xxx" may also encounter similar issue. But the initialization
> can't be in new event callback as discussed in following commit. So this
> patch moves setup_attached_port() to the time point 100ms after received
> the new event.
> 
> Bugzilla ID: 1663
> Fixes: 994635edb2c0 ("app/testpmd: add port attach/detach for multiple 
> process")
> 
> Signed-off-by: Huisong Li <lihuis...@huawei.com>
> ---

Applied to next-net with some rewording of commit message to improve grammar.
Should this patch be cc to stable since it has a Fixes tag?

Reply via email to