From: Eric Kinzie <ekin...@brocade.com> Copy all needed fields from the mode8023ad_private structure in bond_mode_8023ad_conf_get(). This help ensure that a subsequent call to rte_eth_bond_8023ad_setup() is not passed uninitialized data that would result in either incorrect behavior or a failed sanity check.
Fixes: 46fb43683679 ("bond: add mode 4") Signed-off-by: Eric Kinzie <ehkinzie at gmail.com> --- drivers/net/bonding/rte_eth_bond_8023ad.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/net/bonding/rte_eth_bond_8023ad.c b/drivers/net/bonding/rte_eth_bond_8023ad.c index c0f0b99..08f679f 100644 --- a/drivers/net/bonding/rte_eth_bond_8023ad.c +++ b/drivers/net/bonding/rte_eth_bond_8023ad.c @@ -1013,6 +1013,7 @@ bond_mode_8023ad_conf_get(struct rte_eth_dev *dev, conf->aggregate_wait_timeout_ms = mode4->aggregate_wait_timeout / ms_ticks; conf->tx_period_ms = mode4->tx_period_timeout / ms_ticks; conf->update_timeout_ms = mode4->update_timeout_us / 1000; + conf->rx_marker_period_ms = mode4->rx_marker_timeout / ms_ticks; } void -- 1.7.10.4