Hi,

> -----Original Message-----
> From: Rongwei Liu <[email protected]>
> Sent: Monday, March 7, 2022 10:01 AM
> To: Matan Azrad <[email protected]>; Slava Ovsiienko
> <[email protected]>; Ori Kam <[email protected]>; NBU-Contact-
> Thomas Monjalon (EXTERNAL) <[email protected]>; Li Zhang
> <[email protected]>
> Cc: [email protected]; Raslan Darawsheh <[email protected]>;
> [email protected]
> Subject: [PATCH v1] net/mlx5: fix meter creation default state
> 
> Disable means there is no packet drop in the meter. Meter is
> active always but programmed with another CIR/CBS value.
> 
> If the user wants to disable the meter in creation, PMD calls
> the disable() API manually after meter initialized.
> 
> Fixes: 444320186393 ("net/mlx5: support meter creation with policy")
> Cc: [email protected]
> Signed-off-by: Rongwei Liu <[email protected]>

Patch applied to next-net-mlx,

Kindest regards,
Raslan Darawsheh