When kni driver calls eth_kni_start to start device, some fields such as
min_mtu and max_mtu of rte_kni_conf are not initialized. It will cause
kni_ioctl_create create a kni netdevice with a random min_mtu and max_mtu
value. This is unexpected and sometimes we could not change the kni
device mtu with ip link command.

Fixes: ff1e35fb5f83 ("kni: calculate MTU from mbuf size")
Cc: sta...@dpdk.org
Signed-off-by: Harold Huang <baymaxhu...@gmail.com>
---
 drivers/net/kni/rte_eth_kni.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/net/kni/rte_eth_kni.c b/drivers/net/kni/rte_eth_kni.c
index c428caf441..ba58d9dbae 100644
--- a/drivers/net/kni/rte_eth_kni.c
+++ b/drivers/net/kni/rte_eth_kni.c
@@ -124,7 +124,7 @@ eth_kni_start(struct rte_eth_dev *dev)
        struct pmd_internals *internals = dev->data->dev_private;
        uint16_t port_id = dev->data->port_id;
        struct rte_mempool *mb_pool;
-       struct rte_kni_conf conf;
+       struct rte_kni_conf conf = { 0 };
        const char *name = dev->device->name + 4; /* remove net_ */
 
        mb_pool = internals->rx_queues[0].mb_pool;
-- 
2.27.0