If autonegotiation was enabled, driver was not passing the
'auto_pam4_link_speeds' obtained during init and stored in bp->link_info
to bnxt_hwrm_port_phy_cfg(). This would result in an incorrect setting
being passed to the HW during PHY configuration. This in turn, would
result in invalid settings being retrieved and configured in subsequent
application loads resulting in launch failures.

Fixes: c23f9ded0391 ("net/bnxt: support 200G PAM4 link")

Reported-by: Charlie Brtee <c...@hpe.com>
Reviewed-by: Ajit Khaparde <ajit.khapa...@broadcom.com>
Signed-off-by: Somnath Kotur <somnath.ko...@broadcom.com>
---
 drivers/net/bnxt/bnxt_hwrm.c | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/drivers/net/bnxt/bnxt_hwrm.c b/drivers/net/bnxt/bnxt_hwrm.c
index 67ed807dad..df75047e2d 100644
--- a/drivers/net/bnxt/bnxt_hwrm.c
+++ b/drivers/net/bnxt/bnxt_hwrm.c
@@ -3247,6 +3247,8 @@ int bnxt_set_hwrm_link_config(struct bnxt *bp, bool 
link_up)
                link_req.auto_link_speed_mask =
                        bnxt_parse_eth_link_speed_mask(bp,
                                                       dev_conf->link_speeds);
+               link_req.auto_pam4_link_speeds =
+                       bp->link_info->auto_pam4_link_speeds;
        } else {
                if (bp->link_info->phy_type ==
                    HWRM_PORT_PHY_QCFG_OUTPUT_PHY_TYPE_BASET ||
-- 
2.28.0.497.g54e85e7

Reply via email to