24/03/2021 12:36, Cristian Dumitrescu:
> The SWX pipeline instructions work with operands of different types:
> header fields (h.header.field), packet meta-data (m.field), extern
> object mailbox field (e.obj.field), extern function (f.field), action
> data read from table entries (t.field), or immediate values; hence the
> HMEFTI acronym.
> 
> For some pipeline instructions (add/sub, srl/shr, jmplt/jmpgt), only
> the H, M and I cases were handled, while the E, F and T cases were
> disregarded. This is what we fix here.
> 
> Fixes: baf7999303d0 ("pipeline: introduce SWX add instruction")
> Fixes: c88c62943818 ("pipeline: introduce SWX subtract instruction")
> Fixes: b09ba6d0a3c2 ("pipeline: introduce SWX SHL instruction")
> Fixes: e0f51638b715 ("pipeline: introduce SWX SHR instruction")
> Fixes: b3947e25bed4 ("pipeline: introduce SWX jump and return instructions")
> Cc: sta...@dpdk.org
> 
> Signed-off-by: Cristian Dumitrescu <cristian.dumitre...@intel.com>

Applied, thanks