From: Tonghao Zhang <xiangxia.m....@gmail.com>

If user don't set the dv_xmeta_en to 1 or 2,
in the flow_dv_convert_action_set_meta function:

- flow_dv_get_metadata_reg may return the REG_NONE,
  when MLX5_METADATA_FDB enabled for metadata set action.

- reg_to_field(REG_NONE) returns MLX5_MODI_OUT_NONE,
  that is invalid and rdma-core fails.

The rdma-core calltrace:
    dr_action_create_modify_action
    dr_actions_convert_modify_header
    dr_action_modify_sw_to_hw
    dr_action_modify_sw_to_hw_set
    dr_ste_get_modify_hdr_hw_field

Fixes: fcc8d2f716fd ("net/mlx5: extend flow metadata support")
Cc: sta...@dpdk.org

Signed-off-by: Tonghao Zhang <xiangxia.m....@gmail.com>
Signed-off-by: Viacheslav Ovsiienko <viachesl...@nvidia.com>
---
 drivers/net/mlx5/mlx5_flow_dv.c | 10 ++++++++++
 1 file changed, 10 insertions(+)

diff --git a/drivers/net/mlx5/mlx5_flow_dv.c b/drivers/net/mlx5/mlx5_flow_dv.c
index fa2e8f2..bee22f5 100644
--- a/drivers/net/mlx5/mlx5_flow_dv.c
+++ b/drivers/net/mlx5/mlx5_flow_dv.c
@@ -1217,6 +1217,7 @@ struct field_modify_info modify_tcp[] = {
 
        if (reg < 0)
                return reg;
+       MLX5_ASSERT(reg != REG_NON);
        /*
         * In datapath code there is no endianness
         * coversions for perfromance reasons, all
@@ -1438,6 +1439,10 @@ struct field_modify_info modify_tcp[] = {
                reg = flow_dv_get_metadata_reg(dev, attr, error);
                if (reg < 0)
                        return reg;
+               if (reg == REG_NON)
+                       return rte_flow_error_set(error, ENOTSUP,
+                                       RTE_FLOW_ERROR_TYPE_ITEM, item,
+                                       "unavalable extended metadata 
register");
                if (reg == REG_B)
                        return rte_flow_error_set(error, ENOTSUP,
                                          RTE_FLOW_ERROR_TYPE_ITEM, item,
@@ -2446,6 +2451,10 @@ struct field_modify_info modify_tcp[] = {
        reg = flow_dv_get_metadata_reg(dev, attr, error);
        if (reg < 0)
                return reg;
+       if (reg == REG_NON)
+               return rte_flow_error_set(error, ENOTSUP,
+                                         RTE_FLOW_ERROR_TYPE_ACTION, action,
+                                         "unavalable extended metadata 
register");
        if (reg != REG_A && reg != REG_B) {
                struct mlx5_priv *priv = dev->data->dev_private;
 
@@ -7471,6 +7480,7 @@ struct mlx5_hlist_entry *
                reg = flow_dv_get_metadata_reg(dev, attr, NULL);
                if (reg < 0)
                        return;
+               MLX5_ASSERT(reg != REG_NON);
                /*