Hi,Ferruh Yigit

On 2020/9/4 18:34, Ferruh Yigit wrote:
On 8/25/2020 12:53 PM, Wei Hu (Xavier) wrote:
From: "Wei Hu (Xavier)" <xavier.hu...@huawei.com>

This patch changes the log level from NOTICE to INFO.

Signed-off-by: Wei Hu (Xavier) <xavier.hu...@huawei.com>
---
  drivers/net/hns3/hns3_ethdev.c | 4 ++--
  1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/net/hns3/hns3_ethdev.c b/drivers/net/hns3/hns3_ethdev.c
index fca035d4f..3827d3277 100644
--- a/drivers/net/hns3/hns3_ethdev.c
+++ b/drivers/net/hns3/hns3_ethdev.c
@@ -5744,5 +5744,5 @@ static struct rte_pci_driver rte_hns3_pmd = {
  RTE_PMD_REGISTER_PCI(net_hns3, rte_hns3_pmd);
  RTE_PMD_REGISTER_PCI_TABLE(net_hns3, pci_id_hns3_map);
  RTE_PMD_REGISTER_KMOD_DEP(net_hns3, "* igb_uio | vfio-pci");
-RTE_LOG_REGISTER(hns3_logtype_init, pmd.net.hns3.init, NOTICE);
-RTE_LOG_REGISTER(hns3_logtype_driver, pmd.net.hns3.driver, NOTICE);
+RTE_LOG_REGISTER(hns3_logtype_init, pmd.net.hns3.init, INFO);
+RTE_LOG_REGISTER(hns3_logtype_driver, pmd.net.hns3.driver, INFO);


Why making the PMD more verbose by default? You can update the log level
dynamically when need to be more verbose.

Common approach is to set default PMD log level is to 'NOTICE', I think this is
good to make applications more usable.

Currently hns3 PMD driver invokes the private macro named hns3_info in several places, we found that these information wouldn't never be logged.
    hns3_info -> rte_log(RTE_LOG_INFO, hns3_logtype_dirver,...)

To display the related log information, we need to execute the following code in the application, right? Is there any other way?
extern int hns3_logtype_driver;
rte_log_set_level(hns3_logtype_driver, RTE_LOG_INFO);

Thanks, Xavier



Reply via email to