On 5/8/2020 11:38 PM, Dharmik Thakkar wrote:
> On aarch64 platforms, the cycles are counted using either a
> low-resolution generic counter or a high-resolution PMU cycle counter.
> Print the clock frequency along with CPU cycles/packet to identify which
> cycle counter is being used.
> 
> Signed-off-by: Dharmik Thakkar <dharmik.thak...@arm.com>
> Reviewed-by: Honnappa Nagarahalli <honnappa.nagaraha...@arm.com>
> Reviewed-by: Phil Yang <phil.y...@arm.com>

Since 3/5 is independent patch, to not cause that patch hold the patchset, I
will merge rest while we can keep discuss the 3/5.

Except 3/5
Series applied to dpdk-next-net/master, thanks.