You seem to be having an older version of firmware on the card. I will have someone contact you for the newer firmware.
Thanks Ajit On Wed, Aug 7, 2019 at 10:19 PM vikram T <vikra...@gmail.com> wrote: > Hi, > I am trying to run the sample program "hello_world" using the DPDK - 18.11 > version on Braodcom BNXT driver the crash is seen: > > [root@localhost build]# ./helloworld > EAL: Detected 48 lcore(s) > EAL: Detected 2 NUMA nodes > EAL: Multi-process socket /var/run/dpdk/rte/mp_socket > EAL: Probing VFIO support... > EAL: PCI device 0000:02:00.0 on NUMA socket 0 > EAL: probe driver: 8086:1533 net_e1000_igb > EAL: PCI device 0000:18:00.0 on NUMA socket 0 > EAL: probe driver: 14e4:16d9 net_bnxt > bnxt_dev_init(): Broadcom NetXtreme driver bnxt > > bnxt_hwrm_ver_get(): 1.8.3:20.8.156 > bnxt_hwrm_ver_get(): Driver HWRM version: 1.9.2 > __bnxt_hwrm_func_qcaps(): PTP SUPPORTED > bnxt_hwrm_func_resc_qcaps(): error 65535:0:00000000:0000 > bnxt_dev_init(): hwrm query capability failure rc: ffffffea > Segmentation fault > > The same crash is also seen on DPDK-19.05 version. > However with DPDK-17.05 version the sample program runs perfectly fine. > > Below is the output of dpdk-devbind.py -s > > > Network devices using DPDK-compatible driver > ============================================ > 0000:18:00.0 'BCM57417 NetXtreme-E 10GBASE-T RDMA Ethernet Controller 16d9' > drv=igb_uio unused= > > Network devices using kernel driver > =================================== > 0000:02:00.0 'I210 Gigabit Network Connection 1533' if=eno1 drv=igb > unused=igb_uio *Active* > 0000:18:00.1 'BCM57417 NetXtreme-E 10GBASE-T RDMA Ethernet Controller 16d9' > if=eno3d1 drv=bnxt_en unused=igb_uio > 0000:3b:00.0 'Ethernet Controller X710/X557-AT 10GBASE-T 1589' if=enp59s0f0 > drv=i40e unused=igb_uio > 0000:3b:00.1 'Ethernet Controller X710/X557-AT 10GBASE-T 1589' if=enp59s0f1 > drv=i40e unused=igb_uio > 0000:3b:00.2 'Ethernet Controller X710/X557-AT 10GBASE-T 1589' if=enp59s0f2 > drv=i40e unused=igb_uio > 0000:3b:00.3 'Ethernet Controller X710/X557-AT 10GBASE-T 1589' if=enp59s0f3 > drv=i40e unused=igb_uio > 0000:af:00.0 'Ethernet Controller XL710 for 40GbE QSFP+ 1583' if=enp175s0f0 > drv=i40e unused=igb_uio > 0000:af:00.1 'Ethernet Controller XL710 for 40GbE QSFP+ 1583' if=enp175s0f1 > drv=i40e unused=igb_uio > 0000:af:00.2 'Ethernet Controller XL710 for 40GbE QSFP+ 1583' if=enp175s0f2 > drv=i40e unused=igb_uio > 0000:af:00.3 'Ethernet Controller XL710 for 40GbE QSFP+ 1583' if=enp175s0f3 > drv=i40e unused=igb_uio > > Can you help to find the reason for the crash. > > Regards, > Vikram >