The Rx adapter flushes events only if it has BATCH_SIZE events buffered where BATCH_SIZE is set to 32, e.g., if a single packet is sent, it is never passed to eventdev. Fix this issue by adding an event buffer flush either when a Rx queue is found to be empty or the adapter service function has processed the max number of packets for an invocation.
Fixes: 6b83f5935543 ("eventdev: add event buffer flush in Rx adapter") Reported-by: Matias Elo <matias....@nokia.com> Signed-off-by: Nikhil Rao <nikhil....@intel.com> --- lib/librte_eventdev/rte_event_eth_rx_adapter.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/lib/librte_eventdev/rte_event_eth_rx_adapter.c b/lib/librte_eventdev/rte_event_eth_rx_adapter.c index 8d178be..fd3761b 100644 --- a/lib/librte_eventdev/rte_event_eth_rx_adapter.c +++ b/lib/librte_eventdev/rte_event_eth_rx_adapter.c @@ -872,7 +872,7 @@ static uint16_t rxa_gcd_u16(uint16_t a, uint16_t b) break; } - if (buf->count >= BATCH_SIZE) + if (buf->count) rxa_flush_event_buffer(rx_adapter); return nb_rx; -- 1.8.3.1