Hi,

Alena, my assumption is that the Ovs provider is created when you create the 
physical network with GRE isolation (if someone can confirm ...).
When I configured CS RC8 from scratch, I could see the provider and enable it 
in the GUI.
But when I have upgraded from CS 4.1.1 to 4.3.0 RC9, I have preserved the 
existing configuration with the existing physical network.
So my assumption is that the physical network was not updated with the OVS 
provider (such a provider was not needed in CS 4.1.1).

Jessica, I am building CentOS RPM packages from the RC source, using 
"package.sh" script in the source packaging folder. Not aware about the 
difference between "oss" and "noredist".
Also, my setup is for an advanced zone.

Kind Regards,
Florin



-----Original Message-----
From: Jessica Wang [mailto:jessica.w...@citrix.com]
Sent: Friday, March 21, 2014 8:28 PM
To: Florin Dumitrascu; Murali Reddy
Cc: Nguyen Anh Tu (t...@apache.org); dev@cloudstack.apache.org; Alena 
Prokharchyk
Subject: RE: GRE isolation - no in service upgrade (4.1.1 to 4.3.0) - Is your 
zone an Advanced zone or Basic zone? (2)

Florin,
UI doesn't show OVS service provider because database doesn't have OVS service 
provider.
The reasons might be:
(1) You are using oss build (should be using noredist build).
(2) Your zone is a Basic zone (OVS service provider is only supported in 
Advanced zone)


Murali,
Is there other possibility?


Jessica

-----Original Message-----
From: Jessica Wang
Sent: Friday, March 21, 2014 1:15 PM
To: Alena Prokharchyk; Florin Dumitrascu
Cc: Nguyen Anh Tu (t...@apache.org); Murali Reddy; dev@cloudstack.apache.org
Subject: RE: GRE isolation - no in service upgrade (4.1.1 to 4.3.0) - Is your 
zone an Advanced zone or Basic zone?

Florin,

Is your zone an Advanced zone or Basic zone?

Jessica

-----Original Message-----
From: Alena Prokharchyk
Sent: Friday, March 21, 2014 11:53 AM
To: dev@cloudstack.apache.org; Florin Dumitrascu; Jessica Wang
Cc: Nguyen Anh Tu (t...@apache.org); Murali Reddy
Subject: Re: GRE isolation - no in service upgrade (4.1.1 to 4.3.0)

Florin, you have to add the provider to the physical network first, and
then enable it. To add a provider to physical network, use
addNetworkServiceProvider. To enable it after, use
updateNetworkServiceProvider
. Not sure why our UI doesn¹t have this functionality enabled. Jessica,
can you check out if the UI supports adding physical network providers,
and under what conditions?

Thanks,
Alena.


On 3/21/14, 11:47 AM, "Florin Dumitrascu"
<florin.dumitra...@intunenetworks.com> wrote:

>Hi,
>
>I have successfully tested GRE isolation with CS 4.3.0 RC8 installed from
>scratch on a minimal setup.
>
>I have moved then on to upgrading a more complex lab setup from CS 4.1.1
>to CS 4.3.0 RC9.
>I have followed the guidelines here for doing the upgrade:
>http://apache-cloudstack-release-notes.readthedocs.org/en/latest/rnotes.ht
>ml#upgrade-from-4-1-x-to-4-3
>
>Once CS was back up and running, I have created an OVS network offering
>using the GUI fix up from
>https://issues.apache.org/jira/browse/CLOUDSTACK-6162
>
>I tried then to enable the OVS service provider on the physical network,
>but discovered that no such provider is created.
>None in the GUI:
>http://imgur.com/ar8c7sX
>
>And none in the database:
>http://imgur.com/MsIdYrw
>
>So this means I pretty much need to re-configure the whole zone from
>scratch, since I do not know of another way to change the physical
>networks.
>
>If GRE is to be used in the production, this is a major drawback.
>
>Any thoughts ?
>
>Best Regards,
>Florin
>
>
>IMPORTANT NOTE: The information in this e-mail (and any attachments) is
>confidential. The contents may not be disclosed or used by anyone other
>than the addressee. If you are not the intended recipient, please notify
>the sender immediately or telephone: +353 (0)1 6204700. We cannot accept
>any responsibility for the accuracy or completeness of this message as it
>has been transmitted over a public network. If you suspect that the
>message may have been intercepted or amended, please call the sender.


IMPORTANT NOTE: The information in this e-mail (and any attachments) is 
confidential. The contents may not be disclosed or used by anyone other than 
the addressee. If you are not the intended recipient, please notify the sender 