> -----Original Message-----
> From: Rajesh Battala
> Sent: Thursday, May 09, 2013 3:15 PM
> To: Sowmya Krishnan; dev@cloudstack.apache.org
> Subject: RE: [ACS42][QA] Test Plan for Support of Netscaler as external LB in
> VPC
> 
> There are two things, upgrading VPC, and upgrading VPC network offering.
> Upgrading VPC is not supported.
> 
Ok. I am talking about updateVPCOffering. Correct me if I am wrong here: we 
couldn't change VPC offering till now since we had only one offering for VPC: 
Default Offering. Now that we have a new offering (Default Offering with NS), 
shouldn't we allow updating the VPC offering? Otherwise, I don't see how we can 
upgrade the network tier offering to use External device without updating the 
VPC to use NS? 

> Upgrading VPC networking offering (only valid scenario is LB vpc to NS Lb).
> upgrading the network where External device is involved changing the cidr.

This is the network tier offering: updateNetwork. Are you saying this valid 
scenario is supported? Example: updateNetwork from offering which supports 
VPCVR as LB to offering which support NS as LB

> Will update in FS.

Thanks.

> 
> > -----Original Message-----
> > From: Sowmya Krishnan
> > Sent: Thursday, May 9, 2013 2:38 PM
> > To: Rajesh Battala; dev@cloudstack.apache.org
> > Subject: RE: [ACS42][QA] Test Plan for Support of Netscaler as
> > external LB in VPC
> >
> > Thanks Rajesh. Could you please let me know the technical reason why
> > we are not supporting Upgrade of VPC network offering or network tier LB?
> > This limitation needs to be documented. Also, could you please update
> > the same in FS too.
> >
> > > -----Original Message-----
> > > From: Rajesh Battala
> > > Sent: Thursday, May 09, 2013 1:54 PM
> > > To: Sowmya Krishnan; dev@cloudstack.apache.org
> > > Subject: RE: [ACS42][QA] Test Plan for Support of Netscaler as
> > > external LB in VPC
> > >
> > > Please see my comments in-line. Please let me know your comments.
> > >
> > > > -----Original Message-----
> > > > From: Sowmya Krishnan
> > > > Sent: Tuesday, May 7, 2013 3:34 PM
> > > > To: dev@cloudstack.apache.org
> > > > Cc: Rajesh Battala
> > > > Subject: [ACS42][QA] Test Plan for Support of Netscaler as
> > > > external LB in VPC
> > > >
> > > > I am planning to take up test execution for the feature : "Support
> > > > for Netscaler as External Load Balancer in VPC"
> > > > I've written some test cases for the same. Please review and let
> > > > me know if any comments.
> > > > Here are Test cases:
> > > >
> > https://cwiki.apache.org/confluence/display/CLOUDSTACK/Support+for+N
> > > > et
> > > > s
> > > > caler+as+External+Load+Balancer+in+VPC+Tests
> > > >
> > > > Ref FS for the feature is here:
> > > >
> > https://cwiki.apache.org/confluence/display/CLOUDSTACK/Support+of+Ne
> > > > ts
> > > > c
> > > > aler+as+External+LoadBalancing+Provider+in+VPC
> > > >
> > > [Rajesh Battala]
> > > 48. Create VPC with shared NS : It should fail only when tier is
> > > created and implemented with NS as LB ( when NS of type only shared
> > > is available it should
> > > fail) not while creating VPC.
> > >
> > >
> > > Tests cases that should/can be  include :
> > > 1. As External Devices (Netscaler) is involved while tier creation,
> > > cidr should be subset from the super cidr ( new cidr out of super
> > > cidr should not be generated) 2. When tier is created with LB as
> > > Netscaler ( and network is implemented) the VpcVR should have a new
> > > nic attached and the ip of the nic should be the gateway ip
> > > specified while creating the
> > tier.
> > > 3. when tier is created with LB as NS,  when a dedicated NS is
> > > available  after tier got implemented NS state should be in allocated.
> > > 4. when the tier is delete where NS is dedicate, NS allocation state
> > > should be moved to free pool.
> > > 5. Deletion of NS device should fail if the device is in active/used
> > > in the
> > tier.
> > >
> > >
> > > > There are few questions on the FS as I was writing the tests.
> > > > Rajesh, could you please let me know your response for these. I'll
> > > > update the Test plan accordingly.
> > > >
> > > > 1. I am assuming upgrade of VPC offering from Default offering to
> > > > "Default Offering with NS" is allowed. If not, need to update this
> > > > in the FS if there are any limitations on this front.
> > > [Rajesh Battala] Upgrading  not supported currently. We can create
> > > an enhancement to track it.
> > > > 2. On the same lines, upgrade of network offering of the network
> > > > tier is also possible I assume . (For example, from LB provided by
> > > > VpcVirtualRouter to LB provided by Netscaler)
> > > [Rajesh Battala]  Upgrading of LB is possible but not supported currently.
> > > 3. Also on the UI front, currently while creating
> > > > network offering for the tier, if we choose VPC, Netscaler as
> > > > service provider for LB is disabled. We need to enable this.
> > > [Rajesh Battala] yes we need to enable this otherwise VPC n/w
> > > offering cannot be created. I will add it in FS.
> > > >
> > > > Thanks,
> > > > Sowmya