Thank you for reporting this bug to Ubuntu.
Ubuntu 17.04 (zesty) reached end-of-life on January 13, 2018.
Ubuntu 16.10 (yakkety) reached end-of-life on July 20, 2017.
Ubuntu 15.10 (wily) reached end-of-life on July 28, 2016.
Ubuntu 15.04 (vivid) reached end-of-life on February 4, 2016.
Ubuntu 14.10 (utopic) reached end-of-life on July 23, 2015.
Ubuntu 13.10 (saucy) reached end-of-life on July 17, 2014.
Ubuntu 13.04 (raring) reached end-of-life on January 27, 2014.
Ubuntu 12.10 (quantal) reached end-of-life on May 16, 2014.
Ubuntu 12.04 (precise) reached end-of-life on April 28, 2017.
Ubuntu 11.10 (oneiric) reached end-of-life on May 9, 2013.
Ubuntu 11.04 (natty) reached end-of-life on October 28, 2012.
Ubuntu 10.10 (maverick) reached end-of-life on April 10, 2012.
Ubuntu 10.04 (lucid) reached end-of-life on May 9, 2013.
Ubuntu 9.10 (karmic) reached end-of-life on April 30, 2011.
Ubuntu 9.04 (jaunty) reached end-of-life on October 23, 2010.
Ubuntu 8.10 (intrepid) reached end-of-life on April 30, 2010.
Ubuntu 8.04 (hardy) reached end-of-life on May 12, 2011.
Ubuntu 7.10 (gutsy) reached end-of-life on April 18th, 2009.
Ubuntu 7.04 (feisty) reached end-of-life on October 19, 2008.

See this document for currently supported Ubuntu releases:
https://wiki.ubuntu.com/Releases 

We appreciate that this bug may be old and you might not be interested
in discussing it any more. But if you are then please upgrade to the
latest Ubuntu version and re-test. If you then find the bug is still
present in the newer Ubuntu version, please add a comment here telling
us which new version it is in and change the bug status to Confirmed.

** Changed in: upower (Ubuntu)
       Status: New => Invalid

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to upower in Ubuntu.
https://bugs.launchpad.net/bugs/931821

Title:
  ACPI battery information not correctly updating on Acer Aspire ZG5

Status in upower package in Ubuntu:
  Invalid

Bug description:
  My battery status indicator is reporting incorrect times for both
  charge and discharge. The time will fluxuate greatly across values
  much to large to be believed (5 hours to charge, 6 hours to
  discharge). The battery will also not indicate a correct charge
  percentage. Upon reboot, the information appears correct for a few
  minutes, then starts drifting to incorrect values. Attached are the
  hal-device outputs from similar bug report already on Launchpad.

  Charging
  acpitool -b
    Battery #1     : charging, 38.05%, 04:51:32

  Discharging
  acpitool -b
    Battery #1     : charged, 38.17%, 02:14:36

  hal-find-by-capability --capability "ac_adapter" | xargs -n 1 hal-device
  udi = '/org/freedesktop/Hal/devices/computer_power_supply_ac_adapter_ACAD'
    linux.hotplug_type = 2  (0x2)  (int)
    linux.subsystem = 'power_supply'  (string)
    ac_adapter.present = false  (bool)
    info.subsystem = 'power_supply'  (string)
    info.product = 'Generic AC Adapter Device'  (string)
    linux.sysfs_path = 
'/sys/devices/LNXSYSTM:00/device:00/ACPI0003:00/power_supply/ACAD'  (string)
    info.parent = '/org/freedesktop/Hal/devices/computer'  (string)
    info.udi = 
'/org/freedesktop/Hal/devices/computer_power_supply_ac_adapter_ACAD'  (string)
    info.category = 'ac_adapter'  (string)
    info.capabilities = { 'ac_adapter' } (string list)

  hal-find-by-capability --capability "battery" | xargs -n 1 hal-device
  udi = '/org/freedesktop/Hal/devices/computer_power_supply_battery_BAT1'
    linux.hotplug_type = 2  (0x2)  (int)
    linux.subsystem = 'power_supply'  (string)
    battery.type = 'primary'  (string)
    battery.reporting.technology = 'Li-ion'  (string)
    battery.technology = 'lithium-ion'  (string)
    battery.model = 'UM08B74'  (string)
    battery.vendor = 'SIMPLO'  (string)
    battery.voltage.design = 11100  (0x2b5c)  (int)
    battery.voltage.unit = 'mV'  (string)
    info.product = 'UM08B74'  (string)
    battery.reporting.design = 5200  (0x1450)  (int)
    battery.serial = '013B'  (string)
    battery.present = true  (bool)
    battery.reporting.unit = 'mAh'  (string)
    battery.reporting.rate = 658  (0x292)  (int)
    battery.is_rechargeable = true  (bool)
    battery.rechargeable.is_charging = true  (bool)
    battery.rechargeable.is_discharging = false  (bool)
    battery.reporting.current = 1847  (0x737)  (int)
    battery.reporting.last_full = 4949  (0x1355)  (int)
    battery.charge_level.current = 20501  (0x5015)  (int)
    battery.charge_level.last_full = 54933  (0xd695)  (int)
    battery.charge_level.design = 57720  (0xe178)  (int)
    battery.charge_level.rate = 7303  (0x1c87)  (int)
    battery.charge_level.percentage = 37  (0x25)  (int)
    battery.remaining_time = 16973  (0x424d)  (int)
    info.subsystem = 'power_supply'  (string)
    battery.voltage.current = 11472  (0x2cd0)  (int)
    info.udi = 
'/org/freedesktop/Hal/devices/computer_power_supply_battery_BAT1'  (string)
    linux.sysfs_path = 
'/sys/devices/LNXSYSTM:00/device:00/PNP0C0A:00/power_supply/BAT1'  (string)
    info.parent = '/org/freedesktop/Hal/devices/computer'  (string)
    info.category = 'battery'  (string)
    info.capabilities = { 'battery' } (string list)

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/upower/+bug/931821/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to     : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to