Set all lines of filter to weight of 0.
In the Global.cfg, set the weight of the fail for that test to 35.
John Tolmachoff Engineer/Consultant/Owner eServices For You
-----Original Message-----
Hi;
Is there anyway a filter can exit with an exact weight at the end?
Using MaxWeight I can make sure that a filter does not add more than a certain weight to the final weight. But lets say I want to make sure that if the weight is below a certain level when I exit I am at a set weight.
Using:
SKIPIFWEIGHT 30 MINWEIGHTTOFAIL 5 MAXWEIGHT 5
If this filter is triggered then upon exit a total of 5 will be added to the final then the final weight can be at most 34 or at least 5.. what if I want the final weight to be 35 regardless.
Is there a feature that can do this?
Regards, Kami
|
- RE: [Declude.JunkMail] Exiting with fixed weight John Tolmachoff \(Lists\)
- RE: [Declude.JunkMail] Exiting with fixed w... Kami Razvan
- RE: [Declude.JunkMail] Exiting with fix... John Tolmachoff \(Lists\)
- RE: [Declude.JunkMail] Exiting with... Kami Razvan
- [Declude.JunkMail] Vacationing ... Michael Jaworski
- Re: [Declude.JunkMail] Vac... Pete McNeil
- Re: [Declude.JunkMail] Vac... Pete McNeil
- RE: [Declude.JunkMail]... John Tolmachoff \(Lists\)
- Re: [Declude.JunkMail] Exiting with fixed w... Scott Fisher
- RE: [Declude.JunkMail] Exiting with fix... Kami Razvan
- RE: [Declude.JunkMail] Exiting with fixed w... Scott Fisher