OoO En cette soirée bien amorcée du jeudi 29 janvier 2009, vers 22:24, Brice Goglin <brice.gog...@ens-lyon.org> disait :
> Apart from nothing appearing in the log about > MinSpeed/MaxSpeed/AccelFactor (ZAxisMapping doesn't exist for synaptics > anyway), does your touchpad actually behave incorrectly? The synaptic > driver seems to handle float options in non-standard way. So it could > actually be using your float config options without printing anything in > the log. One way to check that would be to run "synclient -l". But > you'll have to enable SHMConfig first, using > <merge key="input.x11_options.SHMConfig" type="string">on</merge> > (beware that this is considered a security risk, so you want to remove > it afterwards). > It seems to work fine here, but nothing appears in the log. synclient -l reports the same values as in fdi file. Therefore, I have just increased the value to get the same behaviour as before. However, I was still unable to scroll because type "bool" seems not to be supported. I have changed to a string value of 1: <merge key="input.x11_options.VertEdgeScroll" type="string">1</merge> Thanks for your help! I suggest to add some tips in NEWS.Debian to let users know that options are now retrieved through HAL. I also had to remove this option: Option "AllowEmptyInput" "off" which was a work around to some other past changes. -- BOFH excuse #374: Its the InterNIC's fault.