When I woke up this morning, one of my boxen had spewed out a ton of errors from one of my SSDs (the root drive), remounted read-only, and went into a kernel panic.
After rebooting everything seems fine, though. I've ran a SMART long test, but as I found out the SMART error log is not supported on this drive. Neither do I have the log of what happened, since / was remounted ro. I've included the output of "smartctl --all /dev/sdc", but I can't see anything that stands out. Yesterday, I had another kernel panic (that seemed related to systemd), so I suspect the (manually built) kernel to be at fault here. The RAM in this machine is all brand new, and I ran memtest less than two weeks ago, so that should be fine. Can anyone look at this log and tell me if there is anything to worry about? Which of the attributes should I look at, so that I know in the future? (And I did a full backup as recently as yesterday that was tested OK at the time, so data loss is not a concern. Everything important is on other drives anyway.) ---<snip>--- smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.19.0-18-generic] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SandForce Driven SSDs Device Model: KINGSTON SV300S37A120G Serial Number: <snip> LU WWN Device Id: 5 0026b7 74703dbf1 Firmware Version: 525ABBF0 User Capacity: 120 034 123 776 bytes [120 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri May 29 08:50:31 2015 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 36) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0025) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0033 095 095 050 Pre-fail Always - 0/6132927 5 Retired_Block_Count 0x0033 100 100 003 Pre-fail Always - 0 9 Power_On_Hours_and_Msec 0x0032 096 096 000 Old_age Always - 4237h+54m+09.420s 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 74 171 Program_Fail_Count 0x000a 000 000 000 Old_age Always - 0 172 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0 174 Unexpect_Power_Loss_Ct 0x0030 000 000 000 Old_age Offline - 65 177 Wear_Range_Delta 0x0000 000 000 000 Old_age Offline - 0 181 Program_Fail_Count 0x000a 000 000 000 Old_age Always - 0 182 Erase_Fail_Count 0x0032 000 000 000 Old_age Always - 0 187 Reported_Uncorrect 0x0012 100 100 000 Old_age Always - 0 189 Airflow_Temperature_Cel 0x0000 024 036 000 Old_age Offline - 24 (Min/Max 15/36) 194 Temperature_Celsius 0x0022 024 036 000 Old_age Always - 24 (Min/Max 15/36) 195 ECC_Uncorr_Error_Count 0x001c 120 120 000 Old_age Offline - 0/6132927 196 Reallocated_Event_Count 0x0033 100 100 003 Pre-fail Always - 0 201 Unc_Soft_Read_Err_Rate 0x001c 120 120 000 Old_age Offline - 0/6132927 204 Soft_ECC_Correct_Rate 0x001c 120 120 000 Old_age Offline - 0/6132927 230 Life_Curve_Status 0x0013 100 100 000 Pre-fail Always - 100 231 SSD_Life_Left 0x0013 100 100 010 Pre-fail Always - 0 233 SandForce_Internal 0x0032 000 000 000 Old_age Always - 2063 234 SandForce_Internal 0x0032 000 000 000 Old_age Always - 2767 241 Lifetime_Writes_GiB 0x0032 000 000 000 Old_age Always - 2767 242 Lifetime_Reads_GiB 0x0032 000 000 000 Old_age Always - 2177 SMART Error Log not supported SMART Self-test Log not supported SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. ---<snip>--- Petter -- "I'm ionized" "Are you sure?" "I'm positive."
pgplc0N368l2E.pgp
Description: OpenPGP digital signature