On 09/21/2014 11:54 AM, Gary Roach wrote:
Hi all
For the last few months I have been plagued by very slow response from
my system. As an example, it takes 2 1/2 minutes to drag and drop 80
files from my email inbox to the trash bin in icedove. It has taken as
high as 5 minutes for iceweasel to load. This problem is not just
these packages but also applies to all of the rest of my programs.
I am using Debian Wheezy with a i5750 4 core processor on a fast Intel
board. I run a kde desktop. All the software is up to date.
I have checked all of the log files and can't find any anomalies.
Rebooting doesn't help.
Using the KDE System Monitor (ksysguard) I have noticed that at least
one of the processors goes to 100% and stays there for long periods
even though there is no noticeable activity in the process tables. The
only other thing I have noticed (the printing just hung up while I am
writing this) is that the hard drive indicator comes on and stays on
during the processor activity. I ran some checks on the hard drive but
found no indication of any hard drive problems.
Has anyone else had a similar problem or have any idea what is going on.
Thanks in advance
Gary R.
After several days of investigation, I am still not sure what is causing
the problem. I have noted the following:
The journaling program jbd2/sda1-8 is taking up most of the I/O time. I
do have noatime set in fstab.
Having two identical machines is very helpful. My wifes system is fast
and never bogs down. Mine is a real dog at this time. I ran iotop on
both systems. In my wifes kjournal will pop to the top of the list for a
very short period when loading a new application. Otherwise iotop is
quiet. On mine kjournal doesn't show at all but jbd2/sda1-8 shows up all
of the time. There is constant activity on my system even when nothing
is happening.
Below is the output from gsmartcontrol. Note that vendor specific
attributes 197 and 198 raw values are 757 and 232 respectively and are
highlighted in pink on the gsmartcontrol program. My wifes computer's
raw values are included in the last column of the smart attributes table
for comparison. Also note that there were no errors reported for my
wifes system. Do I need to replace the drive or is this fixable. Is
this even the root cause of my problems. I'm not too sharp on reading
this data an will appreciate comments from a more knowledgeable person.
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-4-amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Green
Device Model: WDC WD5000AADS-00M2B0
Serial Number: WD-WCAV59765616
LU WWN Device Id: 5 0014ee 25992fc38
Firmware Version: 01.00A01
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Sun Sep 28 18:12:56 2014 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 121) The previous self-test
completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 9960) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 118) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x3037) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE (Wife Raw)
1 Raw_Read_Error_Rate 0x002f 200 200 051
Pre-fail Always - 84123 0
3 Spin_Up_Time 0x0027 114 108 021
Pre-fail Always - 7283 3575
4 Start_Stop_Count 0x0032 100 100 000
Old_age Always - 269 64
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail
Always - 0 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age
Always - 0 0
9 Power_On_Hours 0x0032 051 051 000 Old_age
Always - 35966 31847
10 Spin_Retry_Count 0x0032 100 100 000
Old_age Always - 0 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age
Always - 0 0
12 Power_Cycle_Count 0x0032 100 100 000
Old_age Always - 267 62
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age
Always - 214 48
193 Load_Cycle_Count 0x0032 001 001 000 Old_age
Always - 4000934 2618304
194 Temperature_Celsius 0x0022 110 106 000 Old_age
Always - 37 33
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age
Always - 0 0
197 Current_Pending_Sector 0x0032 191 187 000 Old_age
Always - 757 0
198 Offline_Uncorrectable 0x0030 198 189 000 Old_age
Offline - 232 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age
Always - 0 0
200 Multi_Zone_Error_Rate 0x0008 197 193 000 Old_age
Offline - 723 0
SMART Error Log Version: 1
ATA Error Count: 54177 (device log contains only the most recent five
errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 54177 occurred at disk power-on lifetime: 35960 hours (1498 days +
8 hours)
When the command that caused the error occurred, the device was
active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 34 54 50 e0 Error: UNC at LBA = 0x00505434 = 5264436
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 20 54 50 e0 08 27d+02:56:44.789 READ DMA
ec 00 00 00 00 00 a0 08 27d+02:56:44.781 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 27d+02:56:44.781 SET FEATURES [Set transfer
mode]
Error 54176 occurred at disk power-on lifetime: 35960 hours (1498 days +
8 hours)
When the command that caused the error occurred, the device was
active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 34 54 50 e0 Error: UNC at LBA = 0x00505434 = 5264436
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 20 54 50 e0 08 27d+02:56:41.592 READ DMA
ec 00 00 00 00 00 a0 08 27d+02:56:41.584 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 27d+02:56:41.584 SET FEATURES [Set transfer
mode]
Error 54175 occurred at disk power-on lifetime: 35960 hours (1498 days +
8 hours)
When the command that caused the error occurred, the device was
active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 34 54 50 e0 Error: UNC at LBA = 0x00505434 = 5264436
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 20 54 50 e0 08 27d+02:56:38.459 READ DMA
ec 00 00 00 00 00 a0 08 27d+02:56:38.451 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 27d+02:56:38.451 SET FEATURES [Set transfer
mode]
Error 54174 occurred at disk power-on lifetime: 35960 hours (1498 days +
8 hours)
When the command that caused the error occurred, the device was
active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 34 54 50 e0 Error: UNC at LBA = 0x00505434 = 5264436
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 20 54 50 e0 08 27d+02:56:35.518 READ DMA
ec 00 00 00 00 00 a0 08 27d+02:56:35.510 IDENTIFY DEVICE
ef 03 46 00 00 00 a0 08 27d+02:56:35.510 SET FEATURES [Set transfer
mode]
Error 54173 occurred at disk power-on lifetime: 35960 hours (1498 days +
8 hours)
When the command that caused the error occurred, the device was
active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 34 54 50 e0 Error: UNC at LBA = 0x00505434 = 5264436
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 00 20 54 50 e0 08 27d+02:56:32.353 READ DMA
c8 00 88 68 57 50 e0 08 27d+02:56:32.338 READ DMA
c8 00 20 00 54 50 e0 08 27d+02:56:31.798 READ DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining
LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed: read failure 90% 35888
307316
# 2 Short offline Completed: read failure 90% 35887
330254
# 3 Extended offline Completed: read failure 90% 35887
410646
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Thanks for you help