On Fri, Jan 2, 2009 at 9:30 PM, Bernd Schubert <[email protected]> wrote:
> Hello Bengt,
>
> sil3114 is known to cause data corruption with some disks. So far I only know
> about Seagate, but maybe there issues with newer Samsungs as well?

I've experienced data corruption with a SII 0680 ACLU144 (on an ST
Labs' A-132 card) with a pair of Seagate ST3300622A drives.  I was
using them with MD in a RAID1 configuration.

James.


-- 
To UNSUBSCRIBE, email to [email protected] 
with a subject of "unsubscribe". Trouble? Contact [email protected]

Reply via email to