On 2007-03-18, Hugo Vanwoerkom <[EMAIL PROTECTED]> wrote:
>
> and what this show?
>
> /usr/sbin/smartctl -a -d ata /dev/<drive>
>

I didn't have smartctl installed. I just installed it now, and the
output of smartctl -a -d ata /dev/sda is pasted below. I'm not sure
how to use this tool yet, but from what I understand in the man test I
decided to start with the long self test, which is running now:

smartctl -t long -d ata /dev/sda

smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     FUJITSU MHV2060BH
Serial Number:    NW06T6828MNE
Firmware Version: 00840028
User Capacity:    60,011,642,880 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 4a
Local Time is:    Sun Mar 18 14:50:04 2007 ADT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                 ( 351) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  41) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   046    Pre-fail  Always       
-       62027
  2 Throughput_Performance  0x0005   100   100   030    Pre-fail  Offline      
-       18415616
  3 Spin_Up_Time            0x0003   100   100   025    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   098   098   000    Old_age   Always       
-       8219
  5 Reallocated_Sector_Ct   0x0033   100   100   024    Pre-fail  Always       
-       8589934592000
  7 Seek_Error_Rate         0x000f   100   100   047    Pre-fail  Always       
-       1418
  8 Seek_Time_Performance   0x0005   100   100   019    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0032   098   098   000    Old_age   Always       
-       4832375
 10 Spin_Retry_Count        0x0013   100   100   020    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       599
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       
-       33
193 Load_Cycle_Count        0x0032   098   098   000    Old_age   Always       
-       44131
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       
-       33 (Lifetime Min/Max 13/44)
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       
-       6
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       452263936
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x000f   100   100   060    Pre-fail  Always       
-       14943
203 Run_Out_Cancel          0x0002   100   100   000    Old_age   Always       
-       2628554981278
240 Head_Flying_Hours       0x003e   200   200   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.



-- 
Regards,

Tyler Smit


-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED] 
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]

Reply via email to