Hi all, I have similar worries since I run a fanless EPIA. If load gets to high and I'm not at home, or asleep I want the system to shut down. I wrote this small script using sensors to detect and warn high temps. At very high temps execute shutdown.
A wall-message and a 30 sek timeout is good if I'm at the desk and can connect a fan and abort the shutdown. I run the script with nohup. regards, David. #!/bin/sh HIGH=70 SHUTDOWN_TEMP=85 export HIGH export SHUTDOWN_TEMP while true do # read temp TEMP=`sensors|grep 'CPU Temp'|cut -d+ -f2|cut -d. -f1` if [ "$TEMP" -gt "$HIGH" ]; then echo "High temp: $TEMP > $HIGH" | wall sleep 2 else if [ "$TEMP" -gt "$SHUTDOWN_TEMP" ]; then echo "To hot, shutting down in 30 sek.!" | wall sleep 30 sudo shutdown now else echo temp OK: $TEMP sleep 5 fi fi done On Mar 9, 9:10 am, Bob <[EMAIL PROTECTED]> wrote: > Hi, I'm trying to get my etch MythTV Backend to shutdown automatically > if either the CPU or the Hard drives overheat. > > My motherboard is an ECS K7S5A which has a it87-isa-0290 sensor chip > > from sensors-detect > # Probing for Super-I/O at 0x2e/0x2f > # Trying family `ITE'... Yes > # Found `ITE IT8705F Super IO Sensors' Success! > # (address 0x290, driver `it87') > # > # Probing for Super-I/O at 0x4e/0x4f > # Trying family `ITE'... Yes > # Found `ITE IT8705F Super IO Sensors' Success! > # (address 0x290, driver `it87') > > Sadly with this motherboard it's not possible to read the on die > thermistor without breaking out the soldering irons and modifying it. > > I can't find a way to set the "Overtemperature Shutdown limit" mentioned > in the it87 > documentshttp://www.gelato.unsw.edu.au/lxr/source/Documentation/hwmon/it87 > and I've tried setting temp3_over (CPU) to 40 and used burnK7 up to 53 > degreesC (actual is probably +10 ~ 15) and the system doesn't shutdown. > > I've seen people recommend using sensord to shutdown on overheat but > can't see howto, also this wouldn't do anything for the hard drives, > similarly hddtemp seems to just do reporting with no option to shutdown. > > collectd has options to monitor both but no tools that I can see to do > anything if an error condition arises. > > My reading has led me to believe that the kernel can do at least the CPU > part of this for you, if you've got a better supported sensor chip, > which I don't, but I can't be alone, so what do others do in this situation? > > Thanks, I'm not subscribed at the moment so could you please CC me on > any replys. > > -- > To UNSUBSCRIBE, email to [EMAIL PROTECTED] > with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED] -- To UNSUBSCRIBE, email to [EMAIL PROTECTED] with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]