Hello Debian friends, On september 2005 I bought a new Seagate 160 GB hard disk type ST3160021A UDMA (not SATA) and after some time of good working I am getting some kind of errors, mainly on Debian Sarge startup.
Sometimes my system do not boot because it says something like: " readonly filesystem". The errors occur frequently now, and they often happen on the system "cold" booting, I mean, the first time I switch it on. I cannot tell you the exact messages cause I am not the normal user of this computer. My mother, who uses the computer, has written down the following message, so It could be it is not accurate: "ext3 error device hda1 in start transation: readonly filesystem." I also have some /var/log/messages errors: Mar 26 10:49:23 debian-remix kernel: hda: dma_intr: status=0x51 { DriveReady SeekComplete Error } Mar 26 10:49:23 debian-remix kernel: hda: dma_intr: error=0x40 { UncorrectableError }, LBAsect=43778543, high=2, low=10224111, sector=43778543 Mar 26 10:49:23 debian-remix kernel: end_request: I/O error, dev hda, sector 43778543 I have also have run SMARTCTL tests with the following results: # smartctl -a /dev/hda >From wich I have captured the last 5 errors: "UNC" errors correspond to "UNCorrectable Error in Data" as smartctl man pages states. smartctl version 5.32 Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: ST3160021A Serial Number: 5JS6KB62 Firmware Version: 8.01 Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 2 Local Time is: Sun Mar 26 11:35:22 2006 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 111) minutes. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 058 056 006 Pre-fail Always - 129227943 3 Spin_Up_Time 0x0003 097 096 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 1 5 Reallocated_Sector_Ct 0x0033 098 098 036 Pre-fail Always - 80 7 Seek_Error_Rate 0x000f 073 060 030 Pre-fail Always - 22255207 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 795 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 559 194 Temperature_Celsius 0x0022 033 040 000 Old_age Always - 33 195 Hardware_ECC_Recovered 0x001a 058 056 000 Old_age Always - 129227943 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 TA_Increase_Count 0x0032 100 253 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 18 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 18 occurred at disk power-on lifetime: 794 hours (33 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ef 01 9c e0 Error: UNC at LBA = 0x009c01ef = 10224111 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 b8 5f 01 9c e0 00 00:06:37.747 READ DMA EXT 25 00 c0 57 01 9c e0 00 00:06:37.746 READ DMA EXT 25 00 c8 4f 01 9c e0 00 00:06:37.744 READ DMA EXT 25 00 d0 47 01 9c e0 00 00:06:37.741 READ DMA EXT 25 00 d8 3f 01 9c e0 00 00:06:37.739 READ DMA EXT Error 17 occurred at disk power-on lifetime: 794 hours (33 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ef 01 9c e0 Error: UNC at LBA = 0x009c01ef = 10224111 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 c0 57 01 9c e0 00 00:06:37.747 READ DMA EXT 25 00 c8 4f 01 9c e0 00 00:06:37.746 READ DMA EXT 25 00 d0 47 01 9c e0 00 00:06:37.744 READ DMA EXT 25 00 d8 3f 01 9c e0 00 00:06:37.741 READ DMA EXT 25 00 e0 37 01 9c e0 00 00:06:37.739 READ DMA EXT Error 16 occurred at disk power-on lifetime: 794 hours (33 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ef 01 9c e0 Error: UNC at LBA = 0x009c01ef = 10224111 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 c8 4f 01 9c e0 00 00:06:37.747 READ DMA EXT 25 00 d0 47 01 9c e0 00 00:06:37.746 READ DMA EXT 25 00 d8 3f 01 9c e0 00 00:06:37.744 READ DMA EXT 25 00 e0 37 01 9c e0 00 00:06:37.741 READ DMA EXT 25 00 28 07 01 9c e0 00 00:06:37.739 READ DMA EXT Error 15 occurred at disk power-on lifetime: 794 hours (33 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ef 01 9c e0 Error: UNC at LBA = 0x009c01ef = 10224111 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 d0 47 01 9c e0 00 00:06:37.747 READ DMA EXT 25 00 d8 3f 01 9c e0 00 00:06:37.746 READ DMA EXT 25 00 e0 37 01 9c e0 00 00:06:37.744 READ DMA EXT 25 00 28 07 01 9c e0 00 00:06:37.741 READ DMA EXT 25 00 08 f7 00 9c e0 00 00:06:37.739 READ DMA EXT Error 14 occurred at disk power-on lifetime: 794 hours (33 days + 2 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ef 01 9c e0 Error: UNC at LBA = 0x009c01ef = 10224111 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 d8 3f 01 9c e0 00 00:06:37.747 READ DMA EXT 25 00 e0 37 01 9c e0 00 00:06:37.746 READ DMA EXT 25 00 28 07 01 9c e0 00 00:06:37.744 READ DMA EXT 25 00 08 f7 00 9c e0 00 00:06:37.741 READ DMA EXT 25 00 38 b7 00 9c e0 00 00:06:37.739 READ DMA EXT SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. What do you thing shoud I do? 1-¿Does it make sense to check the disk cable? Or is it an "internal" disk drive error? 2- Should I return the disk to my seller? Normally, restarting the computer solves the problem after a fsck. Sometimes I have also run a "manual" fsck with no aparent data loss. I am concerned about a more serious hard disk failure with real data loss. (I have done backups, no problem ;-) ) Many thanks in advance: Ramiro