В Срд, 21/10/2009 в 15:22 +0400, Andrey Melnikoff пишет: > Винт живее всех живых. Покажи для интересу с sdb то-же самое и поменяй SATA > шлейф на sda > # smartctl -a /dev/sdb smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION === Model Family: Western Digital Caviar Second Generation Serial ATA family Device Model: WDC WD7500AAKS-00RBA0 Serial Number: WD-WCAPT0556130 Firmware Version: 30.04G30 User Capacity: 750 156 374 016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Wed Oct 21 15:27:28 2009 MSD SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (17580) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 217) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 1 3 Spin_Up_Time 0x0003 209 186 021 Pre-fail Always - 6550 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 42 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x000e 200 200 051 Old_age Always - 0 9 Power_On_Hours 0x0032 081 081 000 Old_age Always - 14289 10 Spin_Retry_Count 0x0012 100 253 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0012 100 253 051 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 41 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 39 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 42 194 Temperature_Celsius 0x0022 110 091 000 Old_age Always - 42 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. -- DamirX -- To UNSUBSCRIBE, email to debian-russian-requ...@lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org