On Tue, 18 Jun 2024 17:56:36 +0800 zhangdandan wrote:
> Source: sigscheme
> Version: 0.9.1-2
> Severity: normal
> Tags: FTBFS patch
> User: debian-loonga...@lists.debian.org
> Usertags: loong64
>
> Dear maintainers,
>
> Compiling the sigscheme failed for loong64 in the Debian Package
> Auto-Building environment.
> The build error log is as follows,
> ```
> In file included from ./include/private/gc_priv.h:68,
> from mach_dep.c:16:
> ./include/private/gcconfig.h:496:5: error: #error "The collector has not
> been ported to this machine/OS combination."
> 496 | # error "The collector has not been ported to this machine/OS
> combination."
> | ^~~~~
> ......
> ```
> The full log can be found at
>
https://buildd.debian.org/status/logs.php?pkg=sigscheme&ver=0.9.1-2&arch=loong64.
> Build failed 14 times.
>
> Please consider the patch I attached.
> I have built sigscheme successfully in my local ENV.
>
Please take care of the patch I attached for loong64 in
https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=1073782#5.
For loong64, now sigscheme's support for loong64 has been uploaded to
the unreleased repository of debian-ports.
Please check
http://ftp.ports.debian.org/debian-ports/pool-loong64/main/s/sigscheme/.
Could you add loong64 support in the next upload?
Thanks
Dandan Zhang