> > speeds? The code path on the 7447A models appears to have a settle delay > > of 1 ms after the feature call (which boils down to an OUTB, basically), > > another 0.1 ms after the low_choose_7447a_dfs call which shouldn't take > > very long either. Am I missing something, Ben? > > I'm being over conservative bcs of the voltage change
That's the 1 ms, after which the speed switch happens. Do you think the voltage switch actually takes longer to settle than this? > > I'd not be surprised if the latency was as low as 2 ms total - can we > > profile this reliably in some way? I guess I'll just set the latency to 5 > > ms and see what happens ... > > Last time I looked the on-demand governor was using a workqueue... > anything that has a latency of more than a few dozen usec in a workqueue > shall be shot... That may be right - it's probably the reason for the latency cutoff at 10 ms. People might not be impressed if they try ondemand switching :-) Anyway: is it safe to try, or will I fry my system board? Michael -- To UNSUBSCRIBE, email to [EMAIL PROTECTED] with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]