On Fri, 12 Aug 2005 11:02:25 +0200
Johannes Berg <[EMAIL PROTECTED]> wrote:

> However, only 2 sensors show up in /sys/devices/temperatures, namely
> CPU BOTTOMSIDE (as sensor1_xx) and PWR SUPPLY BOTTOMSIDE (as
> sensor2_xx).
> 
> Is that a bug or is there just some logic skipping the other one for
> whatever reason, maybe because it has no fan? I don't even know if it
> does.

Yes, sensor 0: CPU/INTREPID BOTTOMSIDE is skipped because it has no fan.

-- 
Colin


-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]

Reply via email to